Exhaust gas recirculation (EGR) DDE 4.1
Depending on the operating status, a certain quantity of exhaust gas is returned via both EGR valves into the exhaust tract in order to reduce pollutant emission. EGR valve 1 is mounted on the left and EGR valve 2 on the right of the intake tract.
Components
- EGR valves with vacuum units
- Pressure converter
- Exhaust line
Function
The pressure converters connect the vacuum units with the vacuum supply by means of hoses. Depending on the activation status and controlled by the DDE slave control unit, they switch a variable vacuum to the vacuum unit. The pressure converters are activated by a square-wave signal with duty factors (= variable pulse width) between 5 and 95 %.
Control
The quantity of recirculated exhaust gas influences the mass of the fresh air drawn in: The more exhaust gas is recirculated, the less fresh air is drawn in. Since the mass of fresh air drawn in is known for all operating points with the EGR switched off, the reduction in the mass of fresh air caused by exhaust gas recirculation can be used as a measure for the quantity of recirculated exhaust gas. For the purpose of exhaust gas recirculation control, a set fresh air mass is defined in a characteristic map with following influencing variables for all operating conditions:
- Engine speed
- Injection volume
- Coolant temperature
- Atmospheric pressure
- Intake air temperature
- Reduction in exhaust gas recirculation by idle operation for longer than 28 s
The current setting for exhaust gas recirculation matching (service functions) is an additional influencing variable.
During operation, the quantity of recirculated exhaust gas is controlled by the duty factor at the pressure converter such that the set mass of fresh air defined for the specific operating point is drawn in. With the aid of the mass air flow sensors the control units monitor deviations between the set and actual fresh air mass on both sides. The following faults can occur:
- 0400, "Exhaust gas recirculation (EGR) 2" (negative control deviation)
- 0404, "Exhaust gas recirculation (EGR) 2" (positive control deviation or short-circuit/break)
- 3551, "Exhaust gas recirculation (EGR) 2" (short-circuit/break)
- 3590, "Exhaust gas recirculation (EGR) 1" (short-circuit/break)
- 3610, "Exhaust gas recirculation (EGR) 1" (positive control deviation or short-circuit/break)
- 3615, "Exhaust gas recirculation (EGR) 1" (negative control deviation)
Note: The types of faults must be taken into consideration when evaluating stored fault codes as precise location of a fault is only possible based on the types of fault.
The status of exhaust gas recirculation can be read out of the DDE control unit. The status indicates whether EGR control is active or whether it has been deactivated due to one of the conditions listed below. The status is EGR = 0 if the EGR control is active. Refer to the list below for the statuses when EGR is deactivated. The highest status is output if there are several reasons for EGR activation.
EGR is deactivated:
- Coolant temperature < 16 °C or > 100 °C (status EGR = 11 or 12)
- Engine speed < 500 rpm or > 2000 rpm (status EGR = 8, 13 or 15)
- Required volume > 33 mm^3 (status EGR = 7)
- Atmospheric pressure < 890 mbar (status EGR = 10)
- Battery voltage < 9 V (status EGR = 6)
- Starting engine (status EGR = 9)
- Coasting (status EGR = 4 or 14)
- Engine idling for longer than 15 min (status EGR = 2)
and if following faults occur:
- Fault code 3600: Atmospheric pressure sensor (status EGR = 5)
- All faults in exhaust gas recirculation control (status EGR = 1 or 5)
- Fault codes 0115, 116: Coolant temperature sensor (status EGR = 5)
- Fault codes 0101, 3605: Mass air flow sensor (status EGR = 5)
- Fault codes 0235, 236: Charge pressure sensor (status EGR = 5)
- Fault codes 1E30, 1470, 1E31: Charge pressure control (status EGR = 5)
- Fault code 3620: Mass air flow system fault (status EGR = 5)