Boost pressure control/boost pressure actuator DDE 4.1
Two variable nozzle turbine chargers without a ”wastegate” are used for boost pressure control. They are operated by means of control levers on the turbine housings. The control levers are operated by electrical actuators (electric motors with worm gear and electronic control) that are mounted directly on the turbochargers. The actuators cannot be replaced separately.
Components
- Turbochargers with variable nozzle turbines and electric actuators
Function
The DDE master control unit activates both boost pressure actuators with square-wave signals with duty factors (= variable pulse width) between 5 and 95 %.
Checking variable turbine geometry
The control levers must move between minimum and maximum activation by 35° to 45° angle of rotation. Adjustment must take place rapidly.
Troubleshooting
The following faults may occur in the event of defects in the boost pressure control system.
Fault code 1470, ”boost pressure control”, negative control deviation
Fault code 1E30, ”boost pressure control” with following possible types of fault:
- Boost pressure actuator 1 short-circuit/break
- Positive control deviation
- Equalisation controller
- Fault signal from boost pressure actuator 1
- Charge air hose dropped off (as from DDE software version 44)
Fault code 1E31, ”boost pressure control” with following possible types of fault:
- Boost pressure actuator 2 short-circuit/break
- Fault signal from boost pressure actuator 2
The fault types ”fault signal from boost pressure actuator 1/2” signify that the DDE control unit receives feedback from the boost pressure actuator indicating that a fault has occurred on the boost pressure actuator itself. This may be attributed to efficient voltage supply, overheating, mechanical blocking or a fault in the electronic control of the boost pressure actuator.
Consequences of fault occurring in the boost pressure control system:
- Boost pressure control is deactivated, the boost pressure actuators operate with fixed pulse duty factors.
- Exhaust gas recirculation is deactivated
- In the event of a control deviation in the boost pressure, the injection volume is limited and a substitute value is output for the boost pressure.
Boost pressure control is also deactivated when following faults occur:
- Fault codes 0400, 0404, 3551, 3610, 3615, 3590: Exhaust gas recirculation
- Fault codes 0235, 0236: Boost pressure sensor
- Fault codes 0335, 0336: Crankshaft speed
- Fault codes 0120, 0121: Pedal position sensor 1
- Fault code 0220: Pedal position sensor 2
- Fault codes 0101, 3605: Air mass meter
- Fault code 1E25, 1E26: RPM sensor monitoring
- Fault codes 3005, 3006: Terminal 15
- Fault codes 3565, 3580: Shut-off valve on high pressure pump
- Fault code 3620: Air mass system fault