Fault profiles for the independent heating

Fault profiles for the independent heating

This document provides information on known fault profiles in the independent heating. The following fault profiles are described:

If a fault is determined in the independent / auxiliary heating unit, the control unit is locked. Information of how to unlock the independent / auxiliary heating unit can be found at the end of this document.

Independent / auxiliary heating unit does not start

If the independent / auxiliary heating unit does not start, the most likely cause is a fault lock-out due to the following states:

Information on possible fault code memory entries in the control unit of the independent heating

Observe the following parameters for diagnosis of the independent heating:

Fuel metering pump - coil resistance DP2

9.6 to

10.0

Ohm

Fuel metering pump - coil resistance DP 30.2

4.9 to

5.5

Ohm

Fuel metering pump - delivery volume

205 to

265

ml / h

Fuel extraction in the surge chamber: Distance from the base of the surge chamber

20 to

50

mm

 

Unlocking the independent / auxiliary heating unit

 

 