Exhaust Gas Recirculation Control DDE 3.0
Depending on the operating status, a certain quantity of exhaust gas is returned via the EGR valve into the exhaust tract in order to reduce pollutant emission.
Components
- EGR valve with vacuum unit
- Pressure converter
- Exhaust line with heat exchanger
Function
The pressure converter connects the vacuum unit with the vacuum supply by means of hoses. Depending on the activation status and controlled by the DDE control unit, it switches a variable vacuum to the vacuum unit. The pressure converter is activated by a square-wave signal with duty factors (= variable pulse width) between 5 and 95 %.
Control
The quantity of recirculated exhaust gas influences the mass of the fresh air drawn in: The more exhaust gas is recirculated, the less fresh air is drawn in. Since the mass of fresh air drawn in is known for all operating points with the EGR switched off, the reduction in the mass of fresh air caused by exhaust gas recirculation can be used as a measure for the quantity of recirculated exhaust gas. For the purpose of exhaust gas recirculation control, a set fresh air mass is defined in a characteristic map with following variables for all operating conditions:
- Engine speed
- Injection volume
- Coolant temperature
- Atmospheric pressure
The current setting for exhaust gas recirculation matching (service functions) is an additional influencing variable.
During operation, the quantity of recirculated exhaust gas is controlled by the duty factor at the pressure converter such that the set mass of fresh air defined for the specific operating point is drawn in. Fault code 6 "exhaust gas recirculation (control deviation)" is stored if the control unit detects impermissible deviation between the set and actual fresh air mass.
Conditions for EGR operation:
- Coolant temperature > 25 °C and < 110 °C
- Engine speed > 650 rpm and < 3000 rpm
- Injection volume > 2 mg/stroke and < 29 mg/stroke
- Atmospheric pressure > 930 mbar
EGR is deactivated:
- If the above-specified operating conditions are not fulfilled
- When starting the engine
- Coasting
- Battery voltage < 9 V
and if following faults occur:
- Fault code 5: Needle movement sensor
- Fault code 6: Exhaust gas recirculation (control deviation)
- Fault code 0A. Start of injection control
- Fault code 26: Air mass meter
- Fault code 36: Boost pressure sensor
- Fault code 65: Turbocharger control (control deviation)