Boost Pressure Control DDE 3.0
A turbocharger with variable turbine geometry and without a wastegate is used for boost pressure control. It is operated by means of an adjustment lever on the turbine housing. The adjustment lever is connected by means of a control rod to the vacuum unit on the turbocharger such that the control rod is extended and retracted corresponding to the vacuum applied.
Components
- Turbocharger with variable turbine geometry
- Vacuum unit with control rod
- Pressure converter
Function
The pressure converter links the vacuum unit with the vacuum supply by means of hoses and, depending on the activation status, it switches a variable vacuum to the vacuum unit controlled by the DDE control unit. In this way, the control rod is set in the required position. The pressure converter is activated by a square-wave signal with duty factors (= variable pulse width) between 5 and 95 %.
Checking variable turbine geometry
- Maximum stroke of control rod: 10 mm
- The control rod must be fully RETRACTED (= maximum boost pressure) at 650 mbar vacuum applied at the vacuum unit.
- The control rod must be fully EXTENDED (= minimum boost pressure) at 0 mbar vacuum applied at the vacuum unit.
Troubleshooting
Fault code 65 "turbocharger control" is stored in the event of impermissible control deviation or fault "short/open circuit in pressure converter activation".
Consequences:
- Boost pressure control is deactivated
- Exhaust gas recirculation is deactivated
- The injection volume is limited to 25 mg/stroke in the event of negative control deviation in the boost pressure
Boost pressure control is also deactivated if following faults occur:
- Fault code 06: Exhaust gas recirculation (positive control deviation)
- Fault code 36: Boost pressure sensor