Swirl flaps
Swirl flaps
On the N47oL 4-cylinder diesel engine, the swirl flaps are adjusted steplessly with an electrical swirl-flap actuator.
The controllable swirl flaps are located in the charge ports. Depending on the operating range, the swirl flaps are activated with various pulse duty factors. The further the swirl flaps are closed, the more fresh air is taken in exclusively through the swirl port. This increases the swirl of the fresh air that is taken in.
In the lower load and engine speed range, the swirl flaps are variably closed depending on the operating range. The swirl flaps are fully opened under the following conditions:
- Engine speed > 2250 rpm
- Fuel injection rate > 30 mg/stroke
The position of the swirl flaps is also corrected depending on the ambient pressure. At ambient pressures of less than 880 hPa, the swirl flaps tend to open further.

Fig. 1: sectional view of air collector for intake air with swirl flaps
1 |
swirl flap actuator |
2 |
Adjusting lever for swirl flaps |
3 |
Swirl port |
4 |
Charge port |
5 |
Swirl actuator |
6 |
Connection to throttle valve |
Brief description of components
Electrical swirl-flap actuator
The electrical swirl-flap actuator is activated by the DDE control unit via two signals:
- T_DRAPOS:
PWM signal of 12 V. The pulse width of the PWM signal determines the position of the swirl flaps. - T_DRANEG:
Analog signal of 0 V or 12 V. The voltage of this signal determines the direction of rotation of the actuator:- Close: 0 V
- Open: 12 V
- Close: 0 V
The swirl-flap actuator has an adjustment range of 110°. The adjusting time across the entire adjustment range for opening or closing is approx. 0.1 s.
Position sensor for swirl-flap actuator
The position sensor of the swirl-flap actuator is integrated in the swirl-flap actuator. The position sensor is supplied with a voltage of 5 V by the DDE control unit. The signal of the position sensor is an analog voltage signal.
Notes for Service department
Diagnosis instructions
If the swirl-flap actuator is replaced, the following service function must be run before the replacement:
- Adaptation of swirl-flap actuator
Description and sequence of the adaptation, see corresponding functional description.