Engine mount control DDE6.0/6.2/6.3
The controllable engine mounts are switched to ”hard” or ”soft” corresponding to operating conditions.
Function
The pressure converter connects the engine mounts to the vacuum supply. When activated by the DDE master control unit, the pressure converter switches vacuum to the engine mounts which in turn switch to ”soft”.
The engine mounts are activated at:
- low speeds (under around 60 kph) and
- below engine speeds that are dependent on the coolant temperature (the engine speeds are between 1000 rpm and 1200 rpm)
Troubleshooting
If a defect occurs in the activation of the pressure converter, a fault is stored.
The engine mount control is switched off if at least one of the faults listed occurs for the following functions:
- ”signal, coolant temperature sensor”; fault: 3EE0, 3EE1, 3EE2, 3EE3.
- ”message error, wheel speed”; fault: 49F0, 49F2, 49F3.
Equipment
The control of the engine mount is implemented for diesel engines with more than four cylinders. These engines have a vacuum-controlled engine mount.