Charge-air pressure control/charge-air pressure controller DDE 4.1
Two variable nozzle turbine chargers without a ”wastegate” are used for charge-air pressure control. They are operated by means of control levers on the turbine housings. The control levers are operated by electrical actuators (electric motors with worm gear and electronic control) that are mounted directly on the turbochargers. The actuators cannot be replaced separately.
Components
- Turbochargers with variable nozzle turbines and electric actuators
Function
The DDE master control module activates both charge-air pressure controllers with square-wave signals with duty factors (= variable pulse width) between 5 and 95 %.
Checking variable turbine geometry
The control levers must move between minimum and maximum activation by 35° to 45° angle of rotation. Adjustment must take place rapidly.
Troubleshooting
The following faults may occur in the event of defects in the charge-air pressure control system.
Fault code 1470, ”charge-air pressure control”, negative control deviation
Fault code 1E30, ”charge-air pressure control” with following possible types of fault:
- Charge-air pressure controller 1 short-circuit/break
- Positive control deviation
- Equalisation controller
- Fault signal from charge-air pressure controller 1
- Charge air hose dropped off (as from DDE software version 44)
Fault code 1E31, ”charge-air pressure control” with following possible types of fault:
- Charge-air pressure controller 2 short-circuit/break
- Fault signal from charge-air pressure controller 2
The fault types ”fault signal from charge-air pressure controller 1/2” signify that the DDE control module receives feedback from the charge-air pressure controller indicating that a fault has occurred on the charge-air pressure controller itself. This may be attributed to efficient voltage supply, overheating, mechanical blocking or a fault in the electronic control of the charge-air pressure controller.
Consequences of fault occurring in the charge-air pressure control system:
- Charge-air pressure control is deactivated, the charge-air pressure controllers operate with fixed pulse duty factors.
- Exhaust gas recirculation is deactivated
- In the event of a control deviation in the charge-air pressure, the injection volume is limited and a substitute value is output for the charge-air pressure.
Charge-air pressure control is also deactivated when following faults occur:
- Fault codes 0400, 0404, 3551, 3610, 3615, 3590: Exhaust gas recirculation
- Fault codes 0235, 0236: Charge-air pressure sensor
- Fault codes 0335, 0336: Crankshaft speed
- Fault codes 0120, 0121: Pedal-position sensor 1
- Fault code 0220: Pedal-position sensor 2
- Fault codes 0101, 3605: Air mass meter
- Fault code 1E25, 1E26: RPM sensor monitoring
- Fault codes 3005, 3006: Terminal 15
- Fault codes 3565, 3580: Shut-off valve on high pressure pump
- Fault code 3620: Air mass system fault