Exhaust gas recirculation (EGR) DDE 4.0
Depending on the operating status, a certain quantity of exhaust gas is returned via the EGR valve into the exhaust tract in order to reduce pollutant emission.
Components
- EGR valve with vacuum unit
- Pressure converter
- Exhaust line
Function
The pressure converter connects the vacuum unit with the vacuum supply by means of hoses. Depending on the activation status and controlled by the DDE control unit, it switches a variable vacuum to the vacuum unit. The pressure converter is activated by a square-wave signal with duty factors (= variable pulse width) between 5 and 95 %.
Control
The quantity of recirculated exhaust gas influences the mass of the fresh air drawn in: The more exhaust gas is recirculated, the less fresh air is drawn in. Since the mass of fresh air drawn in is known for all operating points with the EGR switched off, the reduction in the mass of fresh air caused by exhaust gas recirculation can be used as a measure for the quantity of recirculated exhaust gas. For the purpose of exhaust gas recirculation control, a set fresh air mass is defined in a characteristic map with following influencing variables for all operating conditions:
- Engine speed
- Injection volume
- Coolant temperature
- Atmospheric pressure
- Intake air temperature
- Reduction in exhaust gas recirculation by idle operation for longer than 20 s
The current setting for exhaust gas recirculation matching (service functions) is an additional influencing variable.
During operation, the quantity of recirculated exhaust gas is controlled by the duty factor at the pressure converter such that the set mass of fresh air defined for the specific operating point is drawn in. Fault code 0400 "exhaust gas recirculation (control deviation)" is stored if the control unit detects impermissible deviation between the set and actual fresh air mass.
The status of exhaust gas recirculation can be read out of the control unit. The status indicates whether EGR control is active or whether it has been deactivated due to one of the conditions listed below. The status is EGR = 0 if the EGR control is active. Refer to the list below for the statuses when EGR is deactivated. The highest status is output if there are several reasons for EGR activation.
Exhaust gas recirculation is switched off when:
- Coolant temperature < 16 °C or > 100 °C (status EGR = 11 or 12)
- Engine speed < 600 rpm or > 2700 rpm (status EGR = 8, 13 or 15)
- Required volume > 36 mm^3 (status EGR = 7)
- Atmospheric pressure < 880 mbar (status EGR = 10)
- Battery voltage < 9 V (status EGR = 6)
- Starting engine (status EGR = 9)
- Coasting (status EGR = 4 or 14)
- Engine idling for longer than 15 min (status EGR = 2)
and if following faults occur:
- Fault code 0105: Atmospheric pressure sensor (status EGR = 5)
- Fault code 0400: Exhaust gas recirculation control (status EGR = 1 or 5)
- Fault code 0115: Coolant temperature sensor (status EGR = 5)
- Fault code 0100: Mass air flow sensor (status EGR = 5)
- Fault code 0235: Charge pressure sensor (status EGR = 5)