Latent heat accumulator
The latent heat accumulator (LWS) enables rapid heating of the vehicle interior and engine with the aid of a special heat accumulator and a larger auxiliary water pump .
It starts operation automatically as of ignition lock position 1 and is charged with the cooling water heated by the engine. The valves are activated dependent on the following conditions:
Latent heat accumulator
Operating conditions of the LWS
- Latent heat accumulator switched off
The latent heat accumulator is switched off if interior heating is not required or the engine temperature is < 45o C and the LWS temperature is < 30o C. The changeover valve is open (at zero current) , the shut-off valve is closed (power applied) . - Interior heating with engine:
The interior is heated by the engine if the engine is switched off, the engine temperature is > 45 o C and the water valve timing > 0%. The changeover valve is open (at zero current) , the shut-off valve is closed (power applied) .
The interior is heated by the engine when the engine is running and the LWS temperature is less than the engine temperature and this is less than 70 o C. The changeover valve is open (at zero current) , the shut-off valve is closed (power applied) . - Interior heating with latent heat accumulator:
The interior is heated by the latent heat accumulator if the LWS temperature is > 30 o C, the engine temperature < 45 o C and the water valve timing > 0%. The changeover valve and the shut-off valve are closed (power applied to both) . - Engine heating with latent heat accumulator:
The engine is heated by the latent heat accumulator if the LWS temperature is > 30 o C, the engine temperature less than the LWS temperature and the water valve timing = 0%. The changeover valve and the shut-off valve are open (both at zero current) . - Latent heat accumulator heating with engine:
The latent heat accumulator is heated by the engine if the engine temperature is > 70 o C, the LWS temperature is less than the engine temperature and the water valve timing = 0%. The changeover valve and the shut-off valve are open (both at zero current) .
If the water valve clock cycle time is > 0%, the changeover valve is open (at zero current) and the shut-off valve is closed (power applied).
The auxiliary water pump is switched on during operation of the latent heat accumulator when
- Ignition lock position 0 (independent ventilation/residual heat mode), 1 or 2 and water valve timing,left or right
> 0%
- LWS heating active
The auxiliary water pump is switched off during operation of the latent heat accumulator when
- Ignition lock position 0
- Water valve timingleft or right
= 0%
- TemperatureLWS
> 85 o
C