WDSBMW wiring diagrams
← Back

Regular sleeping

This document provides an overview of the typical current values that are measured in an external closed-circuit current measurement with a current measuring clip during regular sleeping.

For the procedure of an external closed-circuit current measurement with measurement system, see document <Observing sleeping by means of external closed-circuit current measurement>.
Regular sleeping without additional wakings to check the coolant temperature:

GR_HI6130_E65_1

No.

Time

Event

Typical current values

1

0 - 3 min

Reaching the idle state

8 to 14 A depending on the equipment.

 

3 - 8 min

Vehicle sleeping

0.8 to 1.5 A depending on the consumer units that are switched on (e.g. map-reading light or glove box light).

2

8 - 9 min

KBM or FRM wakes the vehicle: Consumer unit shutdown.

6 to 10 A depending on the equipment.

 

9 - 30 min or
9 - 60 min

Vehicle sleeping

- Before model year 03/2007: approx. 250 mA
- As of model year 03/2007: approx. 450 mA (relay of the electric fan at terminal 30g).

3

30 or 60 min

Shutdown of terminal 30g

< 30 mA depending on the equipment.