Initializing the power windows
The service function ”Initialize power windows” can be used to initialize the power window drives by means of a diagnosis command.
Notes
Preconditions
Bear the following points in mind so that the initialization runs without faults:
- Adequate battery voltage present, connect charger if necessary.
- Terminal ”R” or terminal ”15” switched on
- All doors closed
Variant differences
In the service function, it is determined whether the power window drives of the front doors are door module to the body gateway module (KGM) or to the door modules (up to 09/2005). The rear power-window drives are connected to the body base module (KBM). Depending on this, the following differences result in the sequence:
Body gateway module (KGM)
The two front power window drives (driver's and passenger's door) are always initialized simultaneously.
During the initialization. the window opens and closes. The anti-trapping protection is active.
Door modules
The initialization is only carried out for one power window drive.
During the initialization. the window opens and closes. No anti-trapping protection is active!
Body basic module (KBM)
The initialization is only carried out for one power window drive.
During initialization, the window is opened and closed twice. No anti-trapping protection is active!
Initialization via operating switches
The initialization of the power window drives can also be carried out using the operating switches.
Sequence for front power windows (KGM or door module)
Use the operating switch in each door to fully close the windows. When the window has reached the upper limit position, keep the switch pulled for approx. 5 seconds.
Sequence for rear power windows (KBM)
The initialization must be run with the power window switch on each door.
- Press the power-window switch towards 'open'. When the window has reached the lower limit position, operate the switch for at least 15 seconds but not longer than 25 seconds.
- Then let go of the power-window switch and immediately pull the switch beyond the 'close' direction. Do not let go of the switch.
- The side window moves to the upper limit position and is then fully opened and closed. During the entire operation, the switch must be pulled beyond the 'Close' direction.
- Once the window has fully closed, the initialization is complete.
During the entire initialization, NO anti-trapping protection is active!