Calibration of body base module
With the software version 03/08, it can occur after programming that the body base module the map-reading lights, vanity mirror light, glove-box light and luggage-compartment light fail.
After programming, the body base module calibrates itself automatically. Different levels at the input and output mean that the calibration does not correspond to the standard value. The body base module erroneously detects a short circuit and switches off the output for the interior lighting.
For fault elimination, the body base module must be recalibrated.
Important
The body base module is not defective and must not be renewed.
1.) Calibration of body base module (variant 1)
- Switch on terminal 15.
- Set the switches for the following lamps to switch position ON:
- Reading light
- Vanity mirror light
- Glove compartment light
- Luggage compartment light
- Reading light
- Start the test step for calibration in the test module.
- Allow vehicle to assume the full sleep mode.
- Once the vehicle has gone to sleep, switch on terminal R.
The body base module is now correctly calibrated and the failed interior lighting functions once again.
If the interior lighting does not function again, continue with chapter 2.).
2.) Calibration of body base module (variant 2)
The following sequence for calibration of the body base module only has to be carried out if the calibration at chapter 1.) could not be finished successfully. First work through the instructions at chapter 1.) completely and check whether the map-reading lights are operative again.
- Uncover the body base module.
- Disconnect the 3-pin connector X13254 from the body base module.
- Disconnect pin 1 and pin 2 at connector X13254. Both pins (signal VA) must be disconnected!
- Reconnect connector X13254 at the body base module
- Start the test step for calibration in the test module.
- Carry out a complete terminal cycle:
- Switch on terminal 15
- Switch on terminal R
- Switch on terminal 30
- Switch on terminal R
- Switch on terminal 15
- Switch on terminal R
- Switch on terminal 30
- Switch on terminal 15
- Reconnect pin 1 and pin 2 at connector X13254. Reinsert the connector.
The body base module is now correctly calibrated and the failed interior lighting functions once again.