Roller cover jams at the top limit position
Repair instruction for roller cover jamming at the top limit position
Roller cover jams at the top limit position.
Repair instruction
Apply current to the roller cover motor from an external power source until the drive is loosened from its jamming position.
- Open the floor panel
- Disconnect the 4-pin connector of the left-hand motor for the drive installed under the load edge trim panel
- Use an external power source to apply current to the motor via the green and white cable
- Move the drivers approx. 100 mm downwards