WDSBMW wiring diagrams
← Back

Regular sleeping

This document provides an overview of the typical current values that are measured in an external closed-circuit current measurement with a current measuring clip during regular sleeping.

For the procedure of an external closed-circuit current measurement with measurement system, see document <Observing sleeping by means of external closed-circuit current measurement>.
Regular sleeping without additional wakings to check the coolant temperature and with transport mode OFF (battery switch ON):

GR_HI6130_E65_1

No.

Time

Event

Typical current values

1

0 - 3 min

Reaching the idle state

10 to 15 A depending on the equipment.

 

3 - 16 min

Vehicle sleeping

0.9 to 1.5 A depending on the consumer units that are switched on (e.g. map-reading light or glove box light).

2

16 - 17 min

PM wakes up the vehicle: First consumer shutdown (roof)

8 to 11 A depending on the equipment.

 

17 - 60 min

Vehicle sleeping

approx. 300 mA.

3

60 min

Second consumer shutdown (body)

< 30 mA depending on the equipment.