Regular sleeping
This document provides an overview of the typical current values that are measured in an external closed-circuit current measurement with a current measuring clip during regular sleeping.
For the procedure of an external closed-circuit current measurement with measurement system, see document <Observing sleeping by means of external closed-circuit current measurement>.
Regular sleeping without additional wakings to check the coolant temperature and with transport mode OFF (battery switch ON):

No. |
Time |
Event |
Typical current values |
1 |
0 - 3 min |
Reaching the idle state |
10 to 15 A depending on the equipment. |
|
3 - 16 min |
Vehicle sleeping |
0.9 to 1.5 A depending on the consumer units that are switched on (e.g. map-reading light or glove box light). |
2 |
16 - 17 min |
PM wakes up the vehicle: First consumer shutdown (roof) |
8 to 11 A depending on the equipment. |
|
17 - 60 min |
Vehicle sleeping |
approx. 300 mA. |
3 |
60 min |
Second consumer shutdown (body) |
< 30 mA depending on the equipment. |