Exhaust-Gas Recirculation (EGR) DDE6 3
Depending on the operating status, a certain quantity of exhaust gas is returned via the EGR valve into the exhaust tract in order to reduce pollutant emission.
Important: On the M67TÜ, two EGR valves are fitted and these are activated individually by the DDE control module. What is described below applies to both of the EGR valves. EGR valve 1 is located in the direction of travel on the right.
Components
- EGR valve with electrical actuator drive
- Exhaust line
Function
The DDE control module controls the pressure converter by means of a square-wave signal with a duty factor (= variable pulse width) between 5 % and 90 %.
Control
The quantity of recirculated exhaust gas influences the mass of the fresh air drawn in: The more exhaust gas is recirculated, the less fresh air is drawn in. The mass of fresh air that passes through the engine at any point on the performance curve when the EGR is switched off is a known quantity. Thus the reduction in the mass of fresh air drawn in due to exhaust gas recirculation is a measure of the quantity of exhaust gas recirculated. During operation, the duty factor on the actuator drive is controlled in such a way that the specified fresh air mass for the operating point concerned is drawn in.
The DDE control module calculates a specified fresh air mass figure for every operating point from the following variables:
- Engine speed
- Injection volume
- Coolant temperature
- Atmospheric pressure
- Intake air temperature
- Reduction in exhaust gas recirculation by idling for longer than 5 min
Exhaust gas recirculation calibration (service function) also affects the specified figure for exhaust gas recirculation.
The causes of cutoff of the exhaust gas recirculation in operation can be read out of the control module. The causes of the cutoff indicate whether EGR control is active or whether it has been deactivated due to one of the conditions listed below.
Exhaust gas recirculation is switched off when:
- Coolant temperature ≤ 15 °C or ≥ 105 °C
- Rotation speed ≤ 500 rpm or ≥ 2200 rpm
- Injection volume too high (dependent on engine speed)
- Atmospheric pressure ≤ 880 mbar
- Battery voltage ≤ 9 V
- Intake-air temperature ≤ 8 °C or ≥ 40 °C
- When starting the engine
- Coasting
- Engine idling for too long
and if following faults occur:
- Fault codes 4501, 4507: exhaust gas recirculation, control deviation
- Diagnostic fault codes 41B0, 41D1, 41E2, 41E3: Exhaust gas recirculation
- Diagnostic fault codes 404B, 405B, 406B, 407B: Exhaust-gas recirculation controller
- Diagnostic fault codes 408A, 408B, 409A, 409B: Status line
- Diagnostic fault codes 3FC0, 3FD0: Mass air flow sensor
- Fault 4060: Atmospheric pressure sensor
- Diagnostic fault codes 4180, 4191, 41A2, 41A3: Charge-air pressure controller
- Fault 4680: Supply voltage 2
- Fault code 3F00: Charge-air pressure sensor
- Fault codes 4520, 4530: charge-air pressure control, control deviation
Monitoring
During controlled operation of the EGR, the control module monitors the mass of the intake air drawn in. If the control module detects a discrepancy between the specified and actual intake air mass that is outside the permissible limits, the following faults may be stored:
- Fault codes 4501, 4507: exhaust gas recirculation, control deviation
If the control module detects a fault in the control of the actuator drive, the following faults may be stored:
- Diagnostic fault codes 41B0, 41D1, 41E2, 41E3: Exhaust gas recirculation, activation