Charge-air pressure controller/boost pressure control DDE5.0/6.0/6.2
A turbocharger with variable turbine geometry and without a ”wastegate” is used for charge-air pressure control.
On the exhaust side there are adjustable blades on the outside of the turbine on rotating bearings. Those blades vary the force applied to the turbine by the exhaust, thereby altering, as required, the charge-air pressure generated by the turbocharger.
An adjusting lever on the turbine housing activates the adjustable guide vanes.
The adjusting lever is operated by means of an electrical charge-air pressure controller (electric motor with worm gear and control electronics) that is mounted to the turbocharger directly. The charge-air pressure controller cannot be replaced separately.
Components
- Turbocharger with variable turbine geometry
- Electrical charge-air pressure controller
Function
The DDE provides the electrical charge-air pressure controller with a pulse-width modulated signal. The operating range of the signal lies between 10 % and 95 %, whereby 10 % means guide vane opened and 95 % means guide vane closed.
The electronics in the charge-air pressure controller convert the PWM signal into an adjusting angle and activate the actuator motor.
Acknowledgment of the set position is only detected indirectly by the DDE via the charge-air pressure sensor. The charge-air pressure controller itself is self-diagnosable and reports faults to the DDE.
Checking variable turbine geometry
The adjusting lever must adjust between minimum and maximum activation by 35° to 45° angle of rotation. Adjustment must take place rapidly.
Troubleshooting
The charge-air-pressure control is monitored for the following faults:
- Positive and negative control deviation
- Fault in activation of the charge-air pressure controller
- Defect in the charge-air pressure controller, e.g. blocked or mechanically defective
- Dropped charge air hose
Consequences of fault occurring in the charge-air pressure control system:
- The turbo pressure control system is switched off; the charge-air pressure controller is activated with a fixed pulse duty factor.
- Exhaust gas recirculation is deactivated
- In the event of a control deviation in the charge-air pressure, the injection volume is limited and a substitute value is output for the charge-air pressure.
Charge-air pressure control is also deactivated when following faults occur:
- Fault in the exhaust-gas recirculation
- Fault on the charge-air pressure sensor
- Fault on the crankshaft speed sensor
- Fault on the pedal-position sensors
- Fault in the air-mass sensor
- Fault at terminal 15
- Fault on the flow regulating valve