Regular sleeping

This document provides an overview of the typical current values that are measured in an external closed-circuit current measurement with a current measuring clip during regular sleeping.

For the procedure of an external closed-circuit current measurement with measurement system, see document <Observing sleeping by means of external closed-circuit current measurement>.
Regular sleeping without additional wakings to check the coolant temperature:

GR_HI6130_E65_1

No.

Time

Event

Typical current values

1

0 - 3 min

Reaching the idle state

6 to 15 A depending on the equipment.

 

3 - 8 min

Vehicle sleeping

0.4 to 1.5 A depending on the consumer units that are switched on (e.g. map-reading light or glove box light).

2

8 - 9 min

FRM wakes up the vehicle: Consumer unit shutdown.

6 to 10 A depending on the equipment.

 

9 - 30 min or
9 - 60 min

Vehicle sleeping

500 to 650 mA depending on the equipment.

3

30 or 60 min

Shutdown of terminal 30g

< 25 mA depending on the equipment.