Perform troubleshooting in the case of overvoltage
This document provides the necessary information and instructions for troubleshooting on vehicles where overvoltage has occurred.
In the vehicle network, the control modules are configured in such a way that they should withstand short voltage peaks above the maximum operating voltage of 16 V without function limitations. However, if voltage peaks while the vehicle is being driven exceed times of more than 300 ms, typically the following possible sporadic symptoms can be observed by the customer:
- the onboard computer goes dark.
- the interior lighting becomes brighter or flickers.
- failure of the ASC/DSC system and ASC+T/DSC indicator and warning lamps light up in the instrument cluster.
- Failure of SZL: problems with windscreen wipers, turn signal indicators, etc.
The possible causes for sporadic occurrences of overvoltage are:
- a load shedding on load-current consumer units or high-current consumer units due to loose contacts.
- a defective alternator.
Procedure
- Read all fault memories with a short test and display all stored fault memory entries ”Overvoltage” with the help of the test module ”Overvoltage troubleshooting”. If present, additional information such as kilometer reading and voltage values are displayed.
- Check battery contact at the positive and negative terminals: Are the connection terminals tight enough?
- Check earth/ground points and earth connections.
- Check plug-in connections and contacts of the high-current consumer units of the vehicle:
- electric auxiliary heater based on PTC principle, if fitted.
- combustion preheating control module (diesel model).
- electric fan.
- other high-current consumer units that might be fitted in the vehicle.
- electric auxiliary heater based on PTC principle, if fitted.
- Check the alternator using the alternator diagnosis: function, plug-in connections and contacts, BSD cable, etc.
- Ask whether the vehicle was jump-started or charged from a truck.