Bit-serial data interface (BSD)
Bit-serial data interface (BSD) in the S54
The bit-serial data interface is a single-wire data bus with a data transfer rate of 1.2 kBd.
The following components in the S54 engine are connected across the bit-serial data interface with the DME/DDE control module:
- Alternator
- Oil condition sensor (depending on variant)
Function:
The following data is interchanged between the DME and the connected components:
- Function commands from the DME to the components
- Identification data of the components to the DME
- Operating values of the components and their functions to the DME
- Fault messages of the components to the DME
Diagnosis:
The connected components have their own diagnosis functionality and monitor the following:
The DME monitors the communication across the bit-serial data interface to the connected components. This means that wire faults are also detected.
- The executed functions are monitored for faults (e.g. defective preheating circuit for the combustion preheating control module)
- Internal faults in the components
If a component detects a fault, it reports the fault across the bit-serial data interface to the DME. The DME then enters the fault in the fault memory.