Glow system
Glow system
The glow system of the N47 4-cylinder diesel engine consists of the following components:
- DDE control module
- electronic glow plug control module
- Ceramic glow plugs
- LIN bus as interface between the DDE control module and combustion preheating control module
The first time the combustion preheating control module is switched on, the electrical resistance of the glow plugs is evaluated at the start of the glow process. A glow plug that is already hot has a significantly higher resistance than a glow plug that is cold. If the resistance leads to the detection of hot glow plugs, the glow plugs are supplied with less energy at the start of glowing. If, on the other hand, cold glow plugs are detected, the glow plugs are supplied with the maximum energy at the start of glowing. This function is referred to as dynamic repeat glowing. It prevents a glow plug that is already hot from being overheated by a second glow process that follows shortly after the first glow process, thus supplying too much energy.
To check the glow system, there are two adapter leads:
- 1-pin, order number 13 6 470
- 12-pin, order number 13 6 460
Function
The required glow plug temperature is determined by the DDE control module on the basis of the following operational parameters:
- Engine speed
- Intake air temperature
- Injection volume
- Ambient pressure
- Vehicle voltage
- Status signal for starter enable
To activate glowing, the DDE sends the required glow plug temperature to the combustion preheating control module.
Across the LIN bus, the DDE also sends the following operating values to the combustion preheating control module:
- Vehicle voltage
- Fuel injection rate per stroke
- Engine speed
The combustion preheating control module uses these three operating values to determine the required current for the glow plugs and supplies the glow plugs with current.
Types of glowing
Glowing is activated in various operating states:
- Preglowing:
Preglowing is activated after switching on terminal 15. Preglowing is terminated when:- The engine speed threshold of 42 rpm is exceeded (starter motor is operated)
or - The preglow time has elapsed. The preglow time depends on the coolant temperature and is specified in a characteristic curve as follows:
- The engine speed threshold of 42 rpm is exceeded (starter motor is operated)
Coolant temperature [°C] |
< -35 |
-25 |
-20 |
-5 |
0 |
5 |
30 |
>30 |
Preglow time [s] |
3,5 |
2,8 |
2,8 |
2,1 |
1,6 |
1,1 |
1,1 |
0 |
- Start standby glowing:
When preglowing has been terminated by the preglow time elapsing, start standby glowing is activated. Start standby glowing is terminated:- After 10 s of start standby glowing
or - When the engine speed threshold of 42 rpm is exceeded.
- After 10 s of start standby glowing
- Start glowing:
Start glowing is activated at every engine start if the coolant temperature is below 75 °C. Start glowing starts after an engine speed threshold of 42 rpm has been exceeded.
Start glowing is terminated:- After the maximum start glow time of 60 s has elapsed
or - After termination of the starting operation
or - When the coolant temperature exceeds 75 °C.
- After the maximum start glow time of 60 s has elapsed
- Emergency glowing:
In the event of a failure in the communication between the DDE and combustion preheating control module for more than 1 second, emergency glowing is triggered for 3 minutes. Here, the combustion preheating control module uses safe values to prevent damage to the glow system. - Hidden glowing:
Up to a coolant temperature of 30 °C, preglowing and start standby glowing are activated as so-called hidden glowing. Hidden glowing is triggered by the following signals:- Driver seat occupancy
- Driver belt buckle
- Valid key
- Terminal R
- Brake operated
- Clutch operated
- Driver seat occupancy
Hidden glowing is triggered a maximum of four times and then only enabled again with the engine start.
Communication
The DDE control module and combustion preheating control module communicate across the LIN bus.
The LIN bus is a bidirectional data interface based on the master-slave principle. The DDE control module is the master controller.
Brief description of components
The following components are described for the glow system:
combustion preheating control module
The combustion preheating control module contains the power output stages for activation of the glow plugs. The combustion preheating control module does not have its own fault memory. Faults in the glow system that are detected by the combustion preheating control module are reported to the DDE by the combustion preheating control module across the LIN bus. The faults are then saved in the DDE fault memory.
If the permitted operating temperature of the combustion preheating control module is exceeded, the combustion preheating control module shuts down any glow process to prevent damage.
Glow plugs
The ceramic glow plugs are designed for a voltage of 7.0 to 10.0 Volts.
During glowing, on-board supply voltage can be applied briefly for rapid heating up. To maintain the glow plug temperature, the glow plugs are supplied with a PWM signal. This sets an effective voltage at the glow plugs that is lower than the on-board supply voltage.

Fig. 1: sectional view of ceramic glow plug
1 |
Ceramic heating element |
5 |
Round connector |
2 |
Positive terminal connection |
6 |
Thread |
3 |
Connection bolt |
7 |
Support tube |
4 |
Gasket |
|
|
Notes for Service department
General information
Important!
The ceramic glow plugs are sensitive to impacts and bending. Glow plugs that are dropped can be damaged.