Combustion preheating system DDE 5.0/5.1
The glowplug system consists of the following components:
- DDE control module
- electronic glowplug control module
- quick-start glowplugs
- Bit serial data interface (BSD) and electrical leads
A heater plug relay as in the case of DDE 4.0 is not fitted.
The quick-start glowplugs are designed for a voltage of between 5.3 and 7.8 Volts. In the initial heating stage, system voltage may also be applied for a short time.
The essential differences from the glowplug systems on previous models are as follows:
- control of the glowplugs is by pulse width modulation
- the glowplug relay has been dispensed with and its function taken over by electronic output stages on the glowplug control module
- an emergency glowplug function has been introduced
- quick-start glowplugs have been introduced
- each of the four glowplug circuits can be diagnosed individually
To check the glow system, there are two adapter leads:
- 1-pin, order number 13 6 470
- 12-pin, order number 13 6 460
in conjunction with 26-pin measurement box, order number 61 1 459
Function
The glowplug control module communicates with the DDE control module via the bit serial data interface.
The required heating output is determined by the DDE control module on the basis of the following operational parameters:
- Coolant temperature
- Vehicle voltage
Two other operational parameters determine the point at which glowplug function is activated and deactivated:
- Engine speed
- Injection volume
The DDE control module transmits the heating request to the glowplug control module via the bit serial data interface. The glowplug control module puts the request into effect by activating the glowplugs by means of a pulse-width modulated signal. In addition, the glowplug control module sends diagnostic and status information back to the DDE control module.
Preheating
At coolant temperatures below 25°C, there is a preheating period of 0.5 seconds. The preheating period increases as the temperature falls, reaching a maximum of 2.7 seconds at a coolant temperature of less than -25°C.
Activation of the glowplug system on the instrument cluster only occurs at coolant temperatures below 0°C.
After-heating
At coolant temperatures below 30°C, there is a temperature-dependent after-heating period to improve idling and exhaust emission characteristics.
Start preheating
Start preheating takes place for approx. 10 seconds if after the preheating time has elapsed the engine is not started and the ignition remain on.
Troubleshooting
The DDE control module monitors communication with the glowplug control module. In the event of a fault on the bit serial data interface, the DDE control module stores the following fault code:
- 4203, Glowplug control module, no communication via bit serial data interface
The glowplug control module monitors activation of the individual glowplugs and is able to detect the following faults and store them for each glowplug:
- Short circuit to ground
- Break
- Excess temperature output stage
If the glowplug control module detects a fault, it reports it to the DDE control module which stores the fault in its fault memory.