EMC measures E81, E87 and R56
Measures to increase electromagnetic compatibility
For certain known fault profiles, design measures have already been implemented in production.
Check these design measures in the event of EMC faults:
- Earth strap on the luggage compartment lid
Fault profile with effect:
corrosion means that the earth connection between the luggage compartment lid and body is lost. This means that the luggage compartment lid oscillates and is electrically undefined.
The reception deteriorates 2 to 3 years after production of the vehicle.
EMC measure E81 / E87

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Earth strap on the luggage compartment lid: |
|
|
EMC measure R56

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Earth strap on the luggage compartment lid: |
|
|
Notes for Service department
Diagnosis instructions
The antenna diagnosis runs as follows:
The self-diagnosis of the antenna diversity is triggered in the test module of the BMW diagnosis system. The self-diagnosis includes a check of the antenna inputs on the basis of a current measurement (direct current). If a fault is found, the antenna diagnosis aborts after the self-diagnosis.
If the self-diagnosis has a positive result, the FM antennas are specifically activated and evaluated with regard to field strength (check of the antennas).
Diagram of antenna diagnosis:

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Normal receive mode (t1 to t2: diversity 2.5 Volt) |
2 |
Self-diagnosis |
3 |
Test of the antennas (t6 to t8: switching pulse 8.5 Volt) |
4 |
Self-diagnosis has positive result (t2 to t5: 5 Volt) |
5 |
Self-diagnosis has negative result: Fault detected (t3 to t4: 0 Volt) |
6 |
Actions triggered by the antenna diagnosis (t9: AM 0 Volt |
No liability can be accepted for printing or other faults. Subject to changes of a technical nature