Mechatronics data synchronization for the DKG.
With the service function 'data synchronization mechatronics', transmission data are transferred from the existing mechatronics into the new mechatronics after replacement of the mechatronics.
The service function 'data synchronization mechatronics' must be carried out after the following tasks:
- Replacing the mechatronics
The instructions of the BMW diagnosis system must be followed without fail, as this is the only to ensure a correct operation.
The following environmental conditions must prevail when the data synchronization for mechatronics is carried out:
- Terminal 15 ON
Sequence of the service function. Sequence 1, replace mechatronics immediately:
- Read transmission data from existing mechatronics
- Replace mechatronics
- Write transmission data into new mechatronics
Sequence of the service function. Sequence 2, replace mechatronics later:
- Display of the read data from existing mechatronics
- Documentation of the displayed data
- Replace mechatronics at a later point in time
- Run the service function again
- Read the documented data of the existing mechatronics into the new mechatronics
Note
The transmission data can only be read out or in when the mechatronics are fitted.