Calibration of glow plugs
The combustion preheating control module saves certain parameters for the individual glow plugs during operation.
Function
The stored parameters must be reset when the glow plugs are replaced. Only parameters on the cylinders where a glow plug was replaced may be reset.
The service function offers two possibilities:
- Reset all cylinders if the glow plugs of all cylinders were replaced.
Reset individual cylinders if the glow plugs of individual cylinders were replaced.