WDSBMW wiring diagrams
← Back

Footwell temperature sensor, rear left

Footwell temperature sensor, rear left

The rear left footwell temperature sensor is a component of the rear automatic climate control (FKA) and it controls the rear air conditioning (with left / right separation).
The sensor measures the delivery temperature directly in the left footwell air outlet in the rear.

A total of 2 rear footwell temperature sensors are installed (left and right). The 2 rear footwell temperature sensors are identical components.

The FKA control module evaluates the signal from the rear left footwell temperature sensor. The signal is sent as a message on the CAN bus. The IHKA control module uses this message to regulate the rear left footwell-flap motor.
If required, the FKA control module switches on the heating element (PTC principle) in the link footwell ventilation duct. This enables additional heating of the air flow.

Functional description

The rear footwell temperature sensor is a hot conductor or NTC resistor (”NTC” stands for ”Negative Temperature Coefficient”).
The hot conductor means that the variable ”temperature” can be converted into the variable ”resistance” which can be electrically evaluated. The current-conducting materials in the hot conductor conduct current better at high temperatures than at low temperatures. That means: With rising temperatures, the resistance falls.

GR_FB6408020

Index

Explanation

Index

Explanation

1

Rear footwell temperature sensor

2

3-pin plug-in connection


Structure and inner circuit

The rear footwell temperature sensor is supplied with 5 Volts by the FKA control module. In order to balance out internal temperature effects, the hot conductor is operated with low current. This means that the outer ambient temperature is decisive for the resistance value.

GR_FB6508020

Index

Explanation

Index

Explanation

1

Hot conductor

 

 


Pin assignments

Pin

Explanation

5 V

Power supply

Kl. 31E

Terminal 31, electronics earth


Characteristic curve and target values

Each temperature change at the hot conductor leads to a change in the voltage signal. The evaluation takes place in the FKA control module.

GR_FB6408022

Index

Explanation

Index

Explanation

1

Temperature in degrees Celsius (°C)

2

Characteristic curve for hot conductor

3

Resistance in Kiloohms (k)

 

 


Observe the following target values for the rear left footwell temperature sensor:

Variable

Value

Power supply

5 V

Temperature range

-40 to 85 °C

Resistance range (measuring range)

1.2 to 100 k


Diagnosis instructions

Failure of the component:

If the left rear footwell temperature sensor fails, the following behaviour is to be expected:

 

No liability can be accepted for printing or other faults. Subject to changes of a technical nature