WDSBMW wiring diagrams
← Back

Charge-air pressure sensor

Charge-air pressure sensor

The charge-air pressure sensor is bolted onto the intake air collector.

The sensor delivers the absolute pressure of the charge air to the Digital Diesel Electronics (DDE) (total of charge-air pressure and ambient pressure).

The purpose of the charge-air pressure sensor is charge-air pressure control.

Functional description

Expansion measurement strips are used to detect the pressure.
The pressure applied deforms a steel membrane in the sensor that is fitted with expansion measurement strips. The changes in resistance in the expansion measurement strips are detected electronically by a measurement bridge and evaluated. The measured voltage is then included as an actual value in the charge-air pressure control.

GR_FB1108067

Index

Explanation

Index

Explanation

1

Intake air collector

2

Charge-air pressure sensor

3

3-pin plug-in connection

 

 


Structure and inner circuit

The charge-air pressure sensor is connected by means of a 3-pin plug-in connection.

The sensor is supplied with 5 Volts and ground by the engine management system.

GR_FB1108020

Index

Explanation

Index

Explanation

1

Charge-air pressure sensor

 

 


Pin assignments

Pin

Explanation

SIG

Charge-air pressure signal

5 V

5 Volts, power supply

Kl. 31E

Terminal 31, electronics earth


Characteristic curve and target values

The charge-air pressure information is sent to the engine management system across a signal line.
The signal for the charge-air pressure, which can be evaluated, fluctuates depending on the pressure. The measuring range of approx. 0.1 to 0.9 Volts corresponds to a charge-air pressure of 50 kPa (0.5 bar) to 330 kPa (3.3 bar).

GR_FB1108068

Index

Explanation

Index

Explanation

1

Voltage

2

Charge-air pressure characteristic curve

3

Temperature

 

 


Observe the following target values for the charge-air pressure sensor:

Variable

Value

Power supply

4.75 to 5.25 Volts

Measuring range for charge-air pressure

0.5 to 3.3 bar

Sensor voltage

0.1 to 0.9 V

Maximum output current

10 mA

Temperature range

-40 °C to 130 °C


Diagnosis instructions

Failure of the component

If the charge-air pressure sensor fails, the following behaviour is to be expected:

No liability can be accepted for printing or other faults. Subject to changes of a technical nature