WDSBMW wiring diagrams
← Back

Exhaust gas pressure sensor after oxidation catalytic converter

Exhaust gas pressure sensor after oxidation catalytic converter

The exhaust gas pressure sensor is attached to a bracket on the engine (protection against high temperatures). The exhaust gas pressure sensor is connected to the exhaust manifold by means of a hose and a pipe.

Functional description

The Digital Diesel Electronics use the signal of the exhaust gas pressure sensor and of the exhaust gas temperature sensor to control the regeneration of the particle filter.
The exhaust gas pressure sensor measures the pressure in the exhaust system after the oxidation catalytic converter. If the exhaust-gas pressure rises above the permitted value of 750 mbar overpressure, the Digital Diesel Electronics initiate regeneration of the particle filter (load of the particle filter exceeded).

In the exhaust gas pressure sensor, a steel-plate membrane converts the exhaust-gas pressure into a path. This path is converted by 4 pressure-sensitive resistors into a voltage signal. The measuring range of the exhaust gas pressure sensor lies at 0.6 to 2.0 bar absolute, which corresponds to a voltage of 1.875 to 4.5 Volts.

GR_FB1108084

Index

Explanation

Index

Explanation

1

Exhaust gas pressure sensor

2

3-pin plug-in connection

3

Oxidation catalytic converter

4

Particle filter


Structure and inner circuit

The exhaust gas pressure sensor is connected by means of a 3-pin plug-in connection.

The sensor is supplied with 5 Volts by the engine management system.

GR_FB1108020

Index

Explanation

Index

Explanation

1

Exhaust gas pressure sensor

 

 


Pin assignments

Pin

Explanation

SIG

Exhaust-gas pressure signal

5 V

5 Volts, power supply

Kl. 31E

Terminal 31, electronics earth


Characteristic curve and target values

The exhaust-gas temperature information is sent to the engine management system across a signal line. The signal for evaluation of exhaust-gas pressure fluctuates depending on the pressure. The measuring range of approx. 1.0 to 4.5 Volts corresponds to a fuel pressure of 60 kPa (0.6 bar) to 200 kPa (2 bar).

The plausibility of the signal is ensured by the following variables:

GR_FB1108085

Index

Explanation

Index

Explanation

1

Signal voltage

2

Exhaust gas pressure sensor characteristic curve

3

Print

 

 


Observe the following target values for the exhaust gas pressure sensor:

Variable

Value

Voltage range

4.75 to 5.25 Volts

Operating pressure

0.6 to 2.0 bar

Response time

Less than 5 ms

Maximum output current

15 mA

Temperature range

-30 °C to 130 °C


Diagnosis instructions

Failure of the component

If the exhaust gas pressure sensor fails, the following behaviour is to be expected:

No liability can be accepted for printing or other faults. Subject to changes of a technical nature