Electric changeover valve, bypass flap EGR cooler

Electric changeover valve, bypass flap EGR cooler

The electric changeover valve is attached to the engine above the EGR cooler.
The EGR cooler has a bypass flap with which the exhaust gas can be fed past the EGR cooler. In the warm-up phase of the engine, the bypass flap is opened to get the oxidation catalytic converter to operating temperature more quickly. It also prevents soiling in the EGR cooler by exhaust-gas residues. The bypass flap is adjusted by a partial-vacuum canister.

Functional description

The engine management system activates the electric changeover valve. This switches the partial vacuum in the system through to the partial-vacuum canister. The partial vacuum applied opens the bypass flap. The partial vacuum applied opens the bypass flap. On venting the diaphragm canister (vacuum system at static pressure), the bypass flap is closed by a spring.

GR_FB1108090

Index

Explanation

Index

Explanation

1

Electric changeover valve for the exhaust flap

2

2-pin plug-in connection

3

EGR cooler

4

Partial-vacuum canister

 

Structure and inner circuit

There is a partial vacuum and ambient pressure at the electropneumatic changeover valve. Depending on activation from the Digital Diesel Electronics, the partial vacuum in the system is switched through to the partial-vacuum canister. Only the positions open or closed are possible.

GR_FB1108047

Index

Explanation

Index

Explanation

1

Electric changeover valve for the bypass flap

 

 


Pin assignments

Pin

Explanation

Kl. 15N

Terminal 15, power supply

SIG

Activation of electric changeover valve


Function principle and target values

Without partial vacuum, the bypass flap is closed, i.e. the exhaust gas flows through the EGR cooler. When partial vacuum is applied, the bypass flap opens the bypass and simultaneously closes the flow to the EGR cooler. The exhaust gas is fed past the EGR cooling directly to the intake air collector.
The bypass of the EGR cooling is opened during EGR operation if the coolant temperature is less than 50 °C.

GR_FB1108091

Index

Explanation

Index

Explanation

1

Bypass flap closed

2

Bypass flap opened


Observe the following target values for the electric changeover valve for the bypass flap:

Variable

Value

Voltage range

9 to 16 V

Operating pressure

0.8 to 1.5 bar

Current consumption

0.55 A

Temperature range

-40 to 140 °C


Diagnosis instructions

Failure of the component

If the electric changeover valve for the bypass flap fails, the following behaviour is to be expected: