Exhaust gas pressure sensor before turbocharger
Exhaust gas pressure sensor before turbocharger
The exhaust backpressure sensor is attached to a bracket on the engine (protection against high temperatures). The exhaust backpressure sensor is connected to the exhaust manifold by means of a hose and a pipe.
Functional description
The exhaust gas pressure sensor before the exhaust turbocharger is required by the Digital Diesel Electronics to optimize regulation of the exhaust gas recirculation rate. The exhaust gas pressure sensor and the exhaust gas temperature sensor enable the Digital Diesel Electronics to regulate the exhaust gas recirculation rate more exactly and more efficiently.
In the exhaust gas pressure sensor, a steel-plate membrane converts the exhaust-gas pressure into a path. This path is converted by 4 pressure-sensitive resistors into a voltage signal. The measuring range of the exhaust gas pressure sensor lies at 100 to 500 kPa absolute, which corresponds to a voltage of 1.0 to 4.5 Volts.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Exhaust gas pressure sensor |
2 |
3-pin plug-in connection |
3 |
Exhaust manifold |
4 |
Turbocharger |
Structure and inner circuit
The exhaust gas pressure sensor is connected by means of a 3-pin plug-in connection.
The sensor is supplied with 5 Volts by the engine management system.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Exhaust gas pressure sensor |
|
|
Pin assignments
Pin |
Explanation |
|---|---|
SIG |
Exhaust-gas pressure signal |
5 V |
5 Volts, power supply |
Kl. 31E |
Terminal 31, electronics earth |
Characteristic curve and target values
The exhaust-gas temperature information is sent to the engine management system across a signal line. The signal for evaluation of exhaust-gas pressure fluctuates depending on the pressure. The measuring range of approx. 1.0 to 4.5 Volts corresponds to an exhaust-gas pressure of 100 kPa (1 bar) to 500 kPa (5 bar).

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Signal voltage |
2 |
Exhaust gas pressure sensor characteristic curve |
3 |
4 |
|
Observe the following target values for the exhaust gas pressure sensor:
Variable |
Value |
|---|---|
Voltage range |
4.9 to 5.1 V |
Operating pressure |
1.0 to 5.0 bar |
Response time |
Less than 5 ms |
Maximum output current |
15 mA |
Temperature range |
-30 °C to 120 °C |
Diagnosis instructions
Failure of the component
If the exhaust gas pressure sensor fails, the following behaviour is to be expected:
- Fault memory entry in the engine control module
- Deactivation of charge-air pressure control
No liability can be accepted for printing or other faults. Subject to changes of a technical nature