WDSBMW wiring diagrams
← Back

Exhaust gas pressure sensor before turbocharger

Exhaust gas pressure sensor before turbocharger

The exhaust backpressure sensor is attached to a bracket on the engine (protection against high temperatures). The exhaust backpressure sensor is connected to the exhaust manifold by means of a hose and a pipe.

Functional description

The exhaust gas pressure sensor before the exhaust turbocharger is required by the Digital Diesel Electronics to optimize regulation of the exhaust gas recirculation rate. The exhaust gas pressure sensor and the exhaust gas temperature sensor enable the Digital Diesel Electronics to regulate the exhaust gas recirculation rate more exactly and more efficiently.

In the exhaust gas pressure sensor, a steel-plate membrane converts the exhaust-gas pressure into a path. This path is converted by 4 pressure-sensitive resistors into a voltage signal. The measuring range of the exhaust gas pressure sensor lies at 100 to 500 kPa absolute, which corresponds to a voltage of 1.0 to 4.5 Volts.

GR_FB1108082

Index

Explanation

Index

Explanation

1

Exhaust gas pressure sensor

2

3-pin plug-in connection

3

Exhaust manifold

4

Turbocharger


Structure and inner circuit

The exhaust gas pressure sensor is connected by means of a 3-pin plug-in connection.

The sensor is supplied with 5 Volts by the engine management system.

GR_FB1108020

Index

Explanation

Index

Explanation

1

Exhaust gas pressure sensor

 

 


Pin assignments

Pin

Explanation

SIG

Exhaust-gas pressure signal

5 V

5 Volts, power supply

Kl. 31E

Terminal 31, electronics earth


Characteristic curve and target values

The exhaust-gas temperature information is sent to the engine management system across a signal line. The signal for evaluation of exhaust-gas pressure fluctuates depending on the pressure. The measuring range of approx. 1.0 to 4.5 Volts corresponds to an exhaust-gas pressure of 100 kPa (1 bar) to 500 kPa (5 bar).

GR_FB1108083

Index

Explanation

Index

Explanation

1

Signal voltage

2

Exhaust gas pressure sensor characteristic curve

3

Print

4

 


Observe the following target values for the exhaust gas pressure sensor:

Variable

Value

Voltage range

4.9 to 5.1 V

Operating pressure

1.0 to 5.0 bar

Response time

Less than 5 ms

Maximum output current

15 mA

Temperature range

-30 °C to 120 °C


Diagnosis instructions

Failure of the component

If the exhaust gas pressure sensor fails, the following behaviour is to be expected:

No liability can be accepted for printing or other faults. Subject to changes of a technical nature