Rail pressure sensor
Rail pressure sensor
The rail-pressure sensor is bolted onto the end of the fuel-distribution pipe (rail).
This sensor delivers the fuel delivery pressure after the high-pressure pump to the engine management system.
The purpose of the rail-pressure sensor is rail pressure control. The signal from the rail-pressure sensor is an important input signal of the engine management system for activation of the volume control valve. The volume control valve is a component of the high-pressure pump.
Functional description
Expansion measurement strips are used to detect the pressure.
The pressure applied deforms a steel membrane in the sensor that is fitted with expansion measurement strips. The changes in resistance in the expansion measurement strips are detected electronically by a measurement bridge and evaluated. The measured voltage is then included as an actual value in the rail pressure control
.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Rail pressure sensor |
2 |
3-pin plug-in connection |
3 |
Fuel-distribution pipe (rail) |
|
|
Structure and inner circuit
The rail-pressure sensor is connected by means of a 3-pin plug-in connection.
The sensor is supplied with 5 Volts by the engine management system.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Rail pressure sensor |
|
|
Pin assignments
Pin |
Explanation |
|---|---|
SIG |
Rail pressure signal |
5 V |
5 Volts, power supply |
Kl. 31E |
Terminal 31, electronics ground |
Characteristic curve and target values
The rail pressure information is sent to the engine management system across a signal line.
The signal for the rail pressure, which can be evaluated, fluctuates depending on the pressure. The measuring range of approx. 0.5 to 4.5 Volts corresponds to a rail pressure of 0 kPa (0 bar) to 25 kPa (250 bar).

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Voltage |
2 |
Characteristic curve for rail pressure |
3 |
|
|
Observe the following target values for the rail-pressure sensor:
Variable |
Value |
|---|---|
Voltage range for rail-pressure sensor |
0.5 to 4.5 Volts |
Measuring range of rail pressure |
0 to 250 bar |
Maximum output current |
10 mA |
Temperature range |
-40 °C to 140 °C |
Diagnosis instructions
Failure of the component
If the rail-pressure sensor fails, the following behaviour is to be expected:
- Fault memory entry in the engine control module
- Emergency operation with substitute value
General information
Diagnosis of the rail-pressure sensor is started as soon as the ignition is switched on. Subsequently, the diagnosis runs continuously every 100 ms.
No liability can be accepted for printing or other faults. Subject to changes of a technical nature