Lambda oxygen sensor before oxidation catalytic converter
Lambda oxygen sensor before oxidation catalytic converter
The Lambda oxygen sensor before the oxidation catalytic converter is a broadband Lambda oxygen sensor (LSU 4.9).
The broadband Lambda oxygen sensor continuously measures the residual oxygen in the exhaust gas. The fluctuating values of the residual oxygen are forwarded to the DDE control module as a voltage signal.
A Lambda oxygen sensor is necessary for compliance with exhaust-gas limit values. The oxygen sensor is required for the quantity mean value adaptation of the injectors. The Lambda oxygen sensor measures the fuel-air ratio. In the event of deviations, the DDE adapts the exhaust gas recirculation rate to the changed fuel-air ratio.
The quantity mean value adaptation is not a ”rapid” control operation, rather a learning procedure. An oxygen sensor deviation is ”learned” in a characteristic map and stored for a sustained period in the DDE control module (EEPROM).
Functional description
The sensor system of the broadband oxygen sensor consists of ceramic layers of zirconium dioxide (laminate). The heating element inserted in the laminate rapidly ensures the required operating temperature of at least 760 °C. The broadband oxygen sensor has 2 cells, a so-called measurement cell and a reference cell. The two cells are coated with electrode made of platinum.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Broadband oxygen sensor |
2 |
6-pin plug connection |
3 |
Housing for oxidation catalytic converter and diesel particle filter |
|
|
The oxygen sensor value measured by the oxygen sensor and the air mass measured by the mass air flow meter are used to determine a mean fuel injection rate across all cylinders. This value is compared with the injection quantity specified by the DDE control module. If there is a deviation, the air mass is adapted to the actual fuel injection rate by adjusting the exhaust gas recirculation (EGR) valve in such a way that the correct oxygen sensor value is set.
Structure and inner circuit
A voltage is applied to the pump cell. This means that oxygen ions are pumped into the measurement cell until a voltage of 450 mV settles between the electrodes of the measurement cell. The resulting pump current is the measured variable for the fuel-air ratio. This enables the oxygen sensor control to set any desired fuel-air ratio in the combustion chamber.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Oxygen sensor heating |
2 |
Reference cell (Nernst cell) |
3 |
Measurement cell (Nernst and pump cell) |
|
|
Pin assignments
Pin |
Explanation |
|---|---|
PWM |
Pulse-width modulated activation of the oxygen sensor heating |
Kl. 15N |
Battery voltage, terminal 15 |
U1 |
Pump voltage at reference cell |
R |
Trimming resistor |
Kl. 31 |
Virtual ground |
U2 |
Nernst voltage |
Characteristic curve and target values
The broadband oxygen sensor can be used to steplessly measure a Lambda value between 0.8 and 2.5 (constant characteristic curve). The Lambda oxygen sensor is most sensitive in the range around Lambda value = 1 am.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Pump current |
2 |
Characteristic curve for Lambda oxygen sensor LSU 4.9 |
3 |
Lambda |
|
|
Observe the following target values for the broadband Lambda oxygen sensor:
Variable |
Value |
|---|---|
Voltage range of oxygen sensor heating |
10.7 to 16.5 V |
Voltage of oxygen sensor heating warming phase |
1.8 to 2 V |
Voltage oxygen sensor heating up to 5 seconds |
12 V |
Voltage oxygen sensor heating up to 6.5 seconds |
9 V |
Operating temperature |
760 °C |
Heater resistor at 20 °C |
2.0 to 3.2 |
Maximum pump current, air |
1.5 mA |
Diagnosis instructions
Failure of the component
If the broadband Lambda oxygen sensor fails, the following behaviour is to be expected:
- Fault memory entry in the engine control module
- Emergency operation with substitute value
- The emissions warning lamp lights up in the instrument cluster
General information
The service function 'Quantity mean value adaptation' must be run if one of the following components was replaced:
- Air-mass flow sensor
- Rail pressure sensor
No liability can be accepted for printing or other faults. Subject to changes of a technical nature