WDSBMW wiring diagrams
← Back

Hot-film air mass meter

Hot-film air mass meter

The hot-film air-mass sensor is attached to the intake muffler.

The hot-film air-mass sensor is a combined sensor.
The hot-film air-mass sensor picks up the actual air mass regardless of the air pressure. In conjunction with other sensors, the engine control module calculates the amount of fuel to be injected.
An intake air temperature sensor is integrated in the hot-film air-mass sensor. The sensor measures the temperature of the intake air before the exhaust turbocharger.

Functional description

An electrically heated measurement cell protrudes into the air flow. The temperature of the measurement cell is always kept constant. The air flow draws heat from the measurement cell. The greater the air-mass flow the more energy must be deployed to keep the temperature of the measurement cell constant.

The characteristic curve of the hot-film air-mass sensor is extended in the negative value range of the air-mass flow (range greater than 550 s). Pulsations due to the uneven firing interval on a cylinder bank also mean that negative air-mass flows occur while the vehicle is being driven. These negative air-mass flows are included in the calculation.

GR_FB1108028

Index

Explanation

Index

Explanation

1

Hot-film air mass meter

2

5-pin plug-in connection

3

Intake muffler

 

 

 

Structure and inner circuit

The sensor is operated with 12 Volts. The intake air temperature sensor is supplied with 5 Volts by the engine management system.

An electronic evaluation unit evaluates the measurement data in the hot-film air-mass sensor. This enables exact detection of the air mass flowing through, including the direction of flow. The sensor element only detects part of the air-mass flow. The total air mass flowing through the meter tube is determined on the basis of a calibration.

GR_FB1108029

Index

Explanation

Index

Explanation

1

Hot-film air mass meter

2

Electronic evaluation unit

3

Intake air temperature sensor

 

 


Pin assignments

Pin

Explanation

Kl. 15N

Terminal 15N, power supply

SIG1

Analogue intake air temperature signal

SIG2

Air mass signal

Kl. 31E

Terminal 31, electronics ground

SIG3

Digital intake air temperature signal


Signal path and target values

The hot-film air-mass sensor has a frequency-coded output signal. The sensor is designed in such a way that return flows (dynamic pulsation in the intake pipe) can be detected and processed both with regard to their amount and direction of flow.

The signal quality for the air mass is temperature-dependent. High accuracy is required to precisely determine the air mass. This is why the air mass signal received in the engine control module must be corrected with the signal of the intake air temperature sensor.

GR_FB1108030

Index

Explanation

Index

Explanation

1

Period

2

Characteristic curve for hot-film air-mass sensor

3

Air mass

 

 


Observe the following target values for the hot-film air-mass sensor:

Variable

Value

Voltage range

7.5 to Volts

Maximum current consumption

Less than 0.1 A

Measuring range of hot-film air-mass sensor

-60 to
850 kg/h

Measuring range of intake-air temperature

-40 °C to 110 °C

Frequency range

1 to 15 kHz

Temperature range

-40 °C to 120 °C


Diagnosis instructions

Failure of the component

If the hot-film air-mass sensor fails, the following behaviour is to be expected:

General information

The hot-film air-mass sensor has a self-diagnosis facility that detects internal sensor faults. Furthermore, the two digital output signals - air mass and temperature signal - are examined electrically and with regard to faults in the value range. If the hot-film air-mass sensor detects an internal fault, the air mass signal is set for a sustained period to Low and the temperature signal is set for a sustained period to High.

No liability can be accepted for printing or other faults. Subject to changes of a technical nature