WDSBMW wiring diagrams
← Back

Right-hand air-distribution-flap motor in the rear climate control

Right-hand air-distribution-flap motor in the rear climate control

The air-distribution-flap motor is the drive for the right-hand air-distribution flap in the rear climate control. The air-distribution flap is used to regulate the ventilation of the vehicle interior in the rear via the right-hand roof air vent.

The drive consists essentially of the following parts:

Functional description

The air-distribution-flap motor is activated and supplied with voltage and ground across the LIN bus by the control module of the automatic rear air conditioning (HKA control module). In the idle state, the HKA control module switches the power supply off.

The air-distribution-flap motor is fitted with an integrated circuit. This circuit controls the coil of the air-distribution-flap motor. The circuit is bus- and diagnosis-compatible.
After activation of the air-distribution-flap motor, the integrated circuit sends a position message (actual position) to the HKA control module.

After the vehicle is stopped and parked and after a specified waiting period (stored in the memory chip of the IHKA control module), the air-distribution-flap motor is moved to a certain parking position. The air-distribution-flap motor is re-initialized to this parking position after starting up.

GR_FB6408049

Index

Explanation

Index

Explanation

1

4-pin plug-in connection

2

Right-hand air-distribution-flap motor in the rear climate control

3

Gearbox output

 

 


Structure and inner circuit

The air-distribution-flap motor is connected to the HKA control module by means of a 4-pin plug-in connection.

GR_FB6408050

Index

Explanation

Index

Explanation

1

Electronic module

2

Right-hand air-distribution-flap motor in the rear climate control


Pin assignments

Pin

Explanation

Terminal 31L

Terminal 31, load ground

LIN in

LIN bus input

LIN out

LIN bus output

U

Power supply


Target values

Observe the following target values for the air-distribution-flap motor in the rear climate control:

Variable

Value

Power supply

12 V

Voltage range

8 to 16 V

Temperature range

-40 ± 85 °C


Diagnosis instructions

The flap motors communicate across the LIN bus with the HKA control module. The flap motors are switched in series on the LIN bus.

The flap motors in the HKA (automatic rear air conditioning) are all the same. During operation, the only difference between them is their programmed address.
Each flap motor is assigned a certain address. The address determines what function the flap motor assumes in the composite system. This address tells e.g. the right-hand air-distribution-flap motor in the rear climate control that messages are being addressed to it (e.g. 'open flap'). This address also tells e.g. the HKA control module which flap motor has sent it a fault message.

After starting the auto-addressing, an address is programmed into the flap motor that is topologically last in the series connection. Then an address is programmed into the topologically second-last flap motor etc. until all the addresses have been assigned. This means that the installation location of the flap motor in the wiring harness decides which address is programmed into the flap motor.

If e.g. during auto-addressing the topologically last flap motor is not connected to the wiring harness of the HKA control module or there is no connection via the LIN bus, the topologically second-last flap motor is erroneously detected as the topologically last flap motor. This means that the wrong address is written into this flap motor. The remaining stepper motors are also given an incorrect address.
Confusing connectors also leads to incorrect addressing.

If a number of flap motors are entered in the fault memory with the fault ”not responding”, there is probably a break in the connection via the LIN bus.
The search for the break (cable, connector, flap motor) must then start at the topologically first of the entered flap motors.

Failure of the component:

If the right-hand air-distribution-flap motor in the rear climate control fails, the following behaviour is to be expected:

No liability can be accepted for printing or other faults. Subject to changes of a technical nature