Fan motor for rear climate control

Fan motor for rear climate control

The fan creates the necessary air-mass flow in the rear climate control. The fan consists of the fan motor and the fan wheel. The fan is integrated in the housing of the rear climate control and is activated by the fan output stage.

Functional description

At the fan output stage, the control module of the rear automatic climate control (HKA control module) specifies the voltage for the fan motor. The specified voltage is output by the HKA control module as a signal on the LIN bus.
Depending on this control signal, the fan motor is activated by the fan output stage.

GR_FB6408075

Index

Explanation

Index

Explanation

1

Rear climate control

2

Blower motor

3

Motor bracket

4

Fan wheel


Structure and inner circuit

The fan motor for the rear climate control is an electric motor.

GR_FB6408071

Index

Explanation

Index

Explanation

1

Fan motor for the rear climate control

 

 


Pin assignments

Pin

Explanation

Terminal 31

Terminal 31, earth connection for fan output stage

U

Activation of the fan output stage


Target values

Observe the following target values for the fan motor:

Variable

Value

Voltage range

9 to 16 V

Maximum current consumption

18 A

Temperature range

-40 to 85 °C


Diagnosis instructions

Failure of the component

If the fan motor in the rear climate control fails, the following behaviour is to be expected:

General information

The fan output stage has diagnostic capability. The corresponding diagnosis information is transferred across the LIN bus to the HKA control module and evaluated there. If it is likely that the fan output stage will overheat, the output voltage is reduced, which leads to reduced fan output.

No liability can be accepted for printing or other faults. Subject to changes of a technical nature