WDSBMW wiring diagrams
← Back

Rear compartment flap motor

Rear compartment flap motor

The rear compartment flap motor is the drive for 2 stratification and 2 ventilation flaps in the rear ventilation duct without left-right separation.

The left-hand stratification flap and the right-hand stratification flap are firmly mounted on a joint shaft.
The stratification flap is used to adjust the air stratification. That means: The proportions of cold and warm air in the air flow towards the rear right-hand ventilation air vents are altered in relation to one another.

In the same way as the stratification flaps, the left-hand and right-hand ventilation flaps are firmly mounted on a joint shaft.
The ventilation flap is used to regulate the air supply into the rear.

The two shafts are connected by means of a cam disk to the rear compartment flap motor.

The drive consists essentially of the following parts:

Functional description

The control module of the rear automatic climate control (FKA control module) evaluates the signal from the rear stratification control. The signal is sent as a message on the CAN bus. The control module of the integrated automatic heating / air-conditioning system (IHKA control module) evaluates this message and activates the rear compartment flap motor across the LIN bus.

The rear compartment flap motor is fitted with an integrated circuit. This circuit controls the coil of the rear compartment flap motor. The circuit is bus- and diagnosis-compatible.
After activation of the rear compartment flap motor, the integrated circuit sends a position message (actual position) to the IHKA control module.

After the vehicle is stopped and parked and after a specified waiting period (stored in the memory chip of the IHKA control module), the rear compartment flap motor is moved to a certain parking position. The rear compartment flap motor is re-initialized to this parking position after starting up.

GR_FB6408049

Index

Explanation

Index

Explanation

1

4-pin plug-in connection

2

Rear compartment flap motor

3

Gearbox output

 

 


Structure and inner circuit

The rear compartment flap motor is connected to the IHKA control module by means of a 4-pin plug-in connection.

GR_FB6408050

Index

Explanation

Index

Explanation

1

Electronic module

2

Rear compartment flap motor


Pin assignments

Pin

Explanation

Terminal 31L

Terminal 31, load ground

LIN in

LIN bus input

LIN out

LIN bus output

U

Power supply


Target values

Comply with the following target values for the rear compartment flap motor:

Variable

Value

Power supply

12 V

Voltage range

8 to 16 V

Temperature range

-40 ± 85 °C


Diagnosis instructions

The flap motors communicate across the LIN bus with the IHKA control module. The flap motors are switched in series on the LIN bus.

The flap motors in the integrated automatic heating / air-conditioning system (IHKA) are all the same. During operation, the only difference between them is their programmed address.
Each flap motor is assigned a certain address. The address determines what function the flap motor assumes in the composite system. This address tells e.g. the rear compartment flap motor that messages are being addressed to it (e.g. 'open flap'). This address also tells e.g. the IHKA control module which flap motor has sent it a fault message.

A precondition for successful addressing of the flap motors is correct coding of the IHKA control module.

After starting the auto-addressing, an address is programmed into the flap motor that is topologically last in the series connection. Then an address is programmed into the topologically second-last flap motor etc. until all the addresses have been assigned. This means that the installation location of the flap motor in the wiring harness decides which address is programmed into the flap motor.

If e.g. during auto-addressing the topologically last flap motor is not connected to the wiring harness of the IHKA control module or there is no connection via the LIN bus, the topologically second-last flap motor is erroneously detected as the topologically last flap motor. This means that the wrong address is written into this flap motor. The remaining stepper motors are also given an incorrect address.
Confusing connectors also leads to incorrect addressing.

If a number of flap motors are entered in the fault memory with the fault ”not responding”, there is probably a break in the connection via the LIN bus.
The search for the break (cable, connector, flap motor) must then start at the topologically first of the entered flap motors.

Failure of the component:

If the rear compartment flap motor fails, the following behaviour is to be expected:

No liability can be accepted for printing or other faults. Subject to changes of a technical nature