Radiator shutter drive unit
Radiator shutter drive unit
An active air flap control via actuator motor (radiator shutter drive) is installed in the front end.
Active air flap control regulates the air supply for the engine and assemblies cooling system by only opening the radiator shutter as it is needed.
Functional description
The engine management system continuously calculates the required cooling output and only opens the radiator shutter when an increased cooling air volume is really required.
While the vehicle is being driven, the closed radiator shutter reduces the warm-up phase of the engine, as operating temperature is reached more quickly if the environment is better encapsulated. The air flow through the radiator creates high aerodynamic drag as the driving speed increases. In higher road speed ranges, the closed radiator shutter improves the aerodynamics. This reduces fuel consumption and thus the emission value.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Air flaps |
2 |
Radiator shutter drive unit |
3 |
4-pin plug-in connection |
|
|
Structure and inner circuit
The radiator shutter drive is DC motor.
The engine management system is connected to the radiator shutter drive across the LIN bus (Local Interconnect Network bus).
The radiator shutter drive is activated via a pulse-width modulated signal (PWM signal) from the engine management system. The radiator shutter has 2 positions: opened and closed.
The radiator shutter drive is supplied with voltage via the junction box.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Electronic evaluation unit |
2 |
Radiator shutter drive unit |
Pin assignments
Pin |
Explanation |
|---|---|
Kl. 31L |
Load ground |
LIN |
Activation of radiator shutter drive |
Kl. 15N |
Power supply |
Conditions required for switch-on and target values
The following evaluation criteria are used for the air flap control:
- Coolant temperature (coolant-temperature sensor and temperature sensor at the radiator outlet, if present)
- Transmission oil temperature
- Engine oil temperature
- Current supply to the characteristic map thermostat (if present)
- Engine load signal
- Engine speed
- Road speed
- Speed of the electric fan
- Trailer detection
Observe the following target values for the radiator shutter drive:
Variable |
Value |
|---|---|
Voltage range |
9 to 16 Volts |
Frequency pulse width modulation |
180 to 220 Hz |
Maximum current consumption |
2.2 A |
Temperature range |
-40 to 120 °C |
Diagnosis instructions
Failure of the component
If the radiator shutter drive fails, the following behaviour is to be expected:
- Fault memory entry in the engine control module
General information
The radiator shutter drive remains in the position it was in when the fault occurred.
The radiator shutter lock is also deactivated if a defect is detected at the coolant-temperature sensor or electric fan.