WDSBMW wiring diagrams
← Back

Recirculated air flap motor

Recirculated air flap motor

The recirculated-air-flap motor is the drive for the recirculated-air flap. The recirculated-air mode is regulated by the recirculated-air flap. In the recirculated air mode, in the event of a high pollutant load, e.g. in a traffic jam, the supply of fresh air can be blocked. The air in the vehicle interior is permanently recirculated.

The drive consists essentially of the following parts:

Functional description

The recirculated-air-flap motor is activated and supplied with voltage and ground across the LIN bus by the control module of the integrated heating / automatic air-conditioning system (IHKA control module). At rest, the IHKA control module switches the power supply off.

The recirculated-air-flap motor is fitted with an integrated circuit. This circuit controls the coil of the recirculated-air-flap motor. The circuit is bus- and diagnosis-compatible.
After activation of the recirculated-air-flap motor, the integrated circuit sends a position message (actual position) to the IHKA control module.

After the vehicle is stopped and parked and after a specified waiting period (stored in the memory chip of the IHKA control module), the recirculated-air-flap motor is moved to a certain parking position. The recirculated-air-flap motor is re-initialized to this parking position after starting up.

GR_FB6408049

Index

Explanation

Index

Explanation

1

2-pin plug-in connection

2

Recirculated air flap motor

3

Gearbox output

 

 


Structure and inner circuit

The recirculated-air-flap motor is connected to the IHKA control module by means of a 4-pin plug-in connection.

GR_FB6408050

Index

Explanation

Index

Explanation

1

Electronic module

2

Recirculated air flap motor


Pin assignments

Pin

Explanation

Terminal 31L

Terminal 31, load ground

LIN in

LIN bus input

LIN out

LIN bus output

U

Power supply


Target values

Comply with the following target values for the recirculated-air-flap motor:

Variable

Value

Power supply

12 V

Voltage range

8 to 16 V

Temperature range

-40 ± 85 °C


Diagnosis instructions

The flap motors communicate across the LIN bus with the IHKA control module. The flap motors are switched in series on the LIN bus.

The flap motors in the IHKA (integrated automatic heating and air conditioning system) are all the same. During operation, the only difference between them is their programmed address.
Each flap motor is assigned a certain address. The address determines what function the flap motor assumes in the composite system. This address tells e.g. the recirculated-air-flap motor that messages are being addressed to it (e.g. 'open flap'). This address also tells e.g. the IHKA control module which flap motor has sent it a fault message.

A precondition for successful addressing of the flap motors is correct coding of the IHKA control module (e.g. IHKA with or without rear automatic climate control).

After starting the auto-addressing, an address is programmed into the flap motor that is topologically last in the series connection. Then an address is programmed into the topologically second-last flap motor etc. until all the addresses have been assigned. This means that the installation location of the flap motor in the wiring harness decides which address is programmed into the flap motor.

If e.g. during auto-addressing the topologically last flap motor is not connected to the wiring harness of the IHKA control module or there is no connection via the LIN bus, the topologically second-last flap motor is erroneously detected as the topologically last flap motor. This means that the wrong address is written into this flap motor. The remaining stepper motors are also given an incorrect address.
Confusing connectors also leads to incorrect addressing.

If a number of flap motors are entered in the fault memory with the fault ”not responding”, there is probably a break in the connection via the LIN bus.
The search for the break (cable, connector, flap motor) must then start at the topologically first of the entered flap motors.

Failure of the component:

If the recirculated-air-flap motor fails, the following behaviour is to be expected: