Sealing cap with brake-fluid level switch

Sealing cap with brake-fluid level switch

There is a damping insert with filling sieve as well as a brake-fluid level switch with float in the brake fluid reservoir. The brake-fluid level switch can be replaced separately. The brake-fluid level switch delivers a signal to the Dynamic Stability Control (DSC). There is a maximum mark and a minimum mark on the brake fluid reservoir.

The brake fluid is a service task of Condition Based Service (CBS).

Functional description

The brake-fluid level switch detects a shortfall in the required brake fluid level in the brake fluid reservoir. The DSC control module sends the signal of the bus system to the instrument cluster. The instrument cluster issues a Check Control message. Normal motion of the brake fluid in the brake fluid reservoir does not normally lead to a Check Control message.

There is a permanent magnet in the moving float; this triggers the reed contact in the brake-fluid level switch firmly fitted in the reservoir. Here, the reed contact converts the float movement into an electrical signal. If the brake fluid level is above the minimum level, the reed contact is closed.

GR_FB3408024

Index

Explanation

Index

Explanation

1

Sealing cap with brake fluid level switch

2

Brake fluid reservoir

3

2-pin plug-in connection

 

 

On the brake-fluid level switch, short circuit or break in wiring cannot be detected. A break in wiring is interpreted as brake fluid loss. A short circuit is not detected.

Structure and inner circuit

The reed contact has the effect of a switch. If the reed contact is activated, ground to the DSC control module is interrupted.

GR_FB3708014

Index

Explanation

Index

Explanation

1

Reed contact in the brake fluid level switch

 

 

Pin assignments

Pin

Explanation

SIG

Reed contact signal


Sectional view and target values

In the event of a leak in one brake circuit, a residual volume remains in the brake fluid reservoir for the other brake circuit (leak protection). In addition, a certain volume for clutch control is integrated in the brake fluid reservoir.

GR_FB3408025

Index

Explanation

Index

Explanation

1

Expansion volume

2

Volume of clutch operation

3

Connection of clutch pipe

4

Residual volume in the event of leakage

5

Connection for brake circuit 2

6

Connection for brake circuit 1

7

Residual volume in the event of leakage

8

Leak volume in the event of leakage

9

Float

10

Magnet ring

11

Reed contact

12

2-pin plug-in connection


Observe the following target values for the brake-fluid level switch:

Variable

Value

Maximum current consumption

15 mA

Maximum contact resistance

500 m

Temperature range

-40 °C to 120 °C


Diagnosis instructions

Failure of the component

If the brake-fluid level switch fails, the following behaviour is to be expected: