Sealing cap with brake-fluid level switch
Sealing cap with brake-fluid level switch
There is a damping insert with filling sieve as well as a brake-fluid level switch with float in the brake fluid reservoir. The brake-fluid level switch can be replaced separately. The brake-fluid level switch delivers a signal to the Dynamic Stability Control (DSC). There is a maximum mark and a minimum mark on the brake fluid reservoir.
The brake fluid is a service task of Condition Based Service (CBS).
Functional description
The brake-fluid level switch detects a shortfall in the required brake fluid level in the brake fluid reservoir. The DSC control module sends the signal of the bus system to the instrument cluster. The instrument cluster issues a Check Control message. Normal motion of the brake fluid in the brake fluid reservoir does not normally lead to a Check Control message.
There is a permanent magnet in the moving float; this triggers the reed contact in the brake-fluid level switch firmly fitted in the reservoir. Here, the reed contact converts the float movement into an electrical signal. If the brake fluid level is above the minimum level, the reed contact is closed.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Sealing cap with brake fluid level switch |
2 |
Brake fluid reservoir |
3 |
2-pin plug-in connection |
|
|
On the brake-fluid level switch, short circuit or break in wiring cannot be detected. A break in wiring is interpreted as brake fluid loss. A short circuit is not detected.
Structure and inner circuit
The reed contact has the effect of a switch. If the reed contact is activated, ground to the DSC control module is interrupted.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Reed contact in the brake fluid level switch |
|
|
Pin assignments
Pin |
Explanation |
|---|---|
SIG |
Reed contact signal |
Sectional view and target values
In the event of a leak in one brake circuit, a residual volume remains in the brake fluid reservoir for the other brake circuit (leak protection). In addition, a certain volume for clutch control is integrated in the brake fluid reservoir.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Expansion volume |
2 |
Volume of clutch operation |
3 |
Connection of clutch pipe |
4 |
Residual volume in the event of leakage |
5 |
Connection for brake circuit 2 |
6 |
Connection for brake circuit 1 |
7 |
Residual volume in the event of leakage |
8 |
Leak volume in the event of leakage |
9 |
Float |
10 |
Magnet ring |
11 |
Reed contact |
12 |
2-pin plug-in connection |
Observe the following target values for the brake-fluid level switch:
Variable |
Value |
|---|---|
Maximum current consumption |
15 mA |
Maximum contact resistance |
500 m |
Temperature range |
-40 °C to 120 °C |
Diagnosis instructions
Failure of the component
If the brake-fluid level switch fails, the following behaviour is to be expected:
- Fault memory entry in the DSC.
- Output of a Check Control message in the instrument cluster
No liability can be accepted for printing or other faults. Subject to changes of a technical nature