WDSBMW wiring diagrams
← Back

Seat belt buckle contact, driver

Seat belt buckle contact, driver

The driver seat belt buckle contact is installed in the belt buckle of the driver's seat. The signal from the driver seat belt buckle contact enables the crash safety module (ACSM) to detect whether the driver's seat belt is fastened or not. ACSM stands for ”Advanced Crash Safety Module”, referred to as the crash safety module.

As of terminal 15 On, the seat belt warning lamp (visual seat belt warning) lights up in the instrument cluster.

When the driver's seat belt is fastened, the visual seat belt warning goes out. The acoustic seat belt warning is switched off. Output of the visual and acoustic seat belt warning depends on the national version.

For the seat belt warning, the signals of the 2 seat belt buckle contacts (driver belt / passenger belt) are monitored separately.

Functional description

The driver seat belt buckle contact is non-contacting. The current consumption of the driver seat belt buckle contact varies dependent on whether the driver belt is fastened or not.

GR_FB7208003

Index

Explanation

Index

Explanation

1

Seat belt buckle

2

Hall-effect sensor

The signal from the driver seat belt buckle contact is read in by the crash safety module (ACSM). The data interchange is analogue.

The driver seat belt buckle contact is permanently monitored by the crash safety module as of terminal R On.

Structure and inner circuit

The driver seat belt buckle contact is supplied with voltage by the crash safety module. A Hall sensor is installed in the driver seat belt buckle contact.

GR_FB7208004

Index

Explanation

Index

Explanation

1

Hall-effect sensor

 

 


Pin assignments

Pin

Explanation

SIG

Signal line and power supply

Terminal 31

Ground connection


Target values

Observe the following target values for the driver seat belt buckle contact:

Variable

Value

Current consumption at status ”driver's seat belt fastened”

12 to 17 mA

Current consumption at status ”driver's seat belt not fastened”

2 to 5 mA

Temperature range

-40 to 85 °C

The interface in the crash safety module (ACSM) is pulsed. As these are not static values (the pulse is applied every 306 milliseconds for only 2 milliseconds), the values can only be measured using an oscilloscope.


Diagnosis instructions

Failure of the component

If the driver seat belt buckle contact fails, the following behaviour is to be expected: