Drainage coil valve
Drainage coil valve
The drainage coil valve is attached to the tandem pump.
When the vehicle is being driven straight ahead, the volumetric flow of the tandem pump is throttled on the intake side by the application of current. This lowers the pressure of the circulating flow. The tandem pump consumes less power. This lowers CO2 emissions.
Functional description
The oil flow flows before the tandem pump through the drainage coil valve. The control module for vertical dynamics management activates the drainage coil valve when the vehicle is being driven straight ahead. Activation is carried out when the vehicle is being driven straight ahead as well as when the vehicle is stationary (engine running). This lowers the loss due to unnecessary pump output.
The delivery volume of the tandem pump is proportional to the speed provided the speed lies below the breakaway speed of the tandem pump
(engine speed approx. 1000 rpm).

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Tandem pump (power-steering pump and active roll stabilization) |
2 |
Connection for radial piston pump |
3 |
Connection for vane-type pump |
4 |
Drainage coil valve |
5 |
2-pin plug-in connection |
6 |
Supply to tandem pump |
7 |
ECO valve (power-steering pump) |
|
|
Structure and inner circuit
The drainage coil valve is connected by means of a 2-pin plug-in connection.
The drainage coil valve is a solenoid valve. The VDM control module supplies the drainage coil valve with current (approx. 0.85 Ampere).

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Drainage coil valve |
|
|
Pin assignments
Pin |
Explanation |
|---|---|
12 V |
Power supply drainage coil valve |
Terminal 31E |
Terminal 31, electronics earth for drainage coil valve |
Characteristic curve and target values for tandem pump
During idling, the pump speed is approx. 750 rpm. At this idle speed, the tandem pump delivers a volumetric flow of approx. 5 l/min at approximately 3 bar. This ensures adequate system dynamics even at idle speed. At a pump speed of 1250 rpm, the maximum volumetric flow is limited to 9 l/min.

Index |
Explanation |
Index |
Explanation |
|---|---|---|---|
1 |
Pump speed |
2 |
Characteristic curve for tandem pump |
3 |
Volumetric flow |
|
|
Observe the following target values for the drainage coil valve:
Variable |
Value |
|---|---|
Voltage range |
8 to 16 V |
Response time at 20 °C and 13 V |
≤ 40 ms |
Current consumption at 25 °C and 13 V |
approx. 1 A |
Temperature range |
-40 °C to 140 °C |
Diagnosis instructions
Failure of the component
If the drainage coil valve fails, the following behaviour is to be expected:
- Fault memory entry in the VDM control module
No liability can be accepted for printing or other faults. Subject to changes of a technical nature