Drainage coil valve

Drainage coil valve

The drainage coil valve is attached to the tandem pump.

When the vehicle is being driven straight ahead, the volumetric flow of the tandem pump is throttled on the intake side by the application of current. This lowers the pressure of the circulating flow. The tandem pump consumes less power. This lowers CO2 emissions.

Functional description

The oil flow flows before the tandem pump through the drainage coil valve. The control module for vertical dynamics management activates the drainage coil valve when the vehicle is being driven straight ahead. Activation is carried out when the vehicle is being driven straight ahead as well as when the vehicle is stationary (engine running). This lowers the loss due to unnecessary pump output.

The delivery volume of the tandem pump is proportional to the speed provided the speed lies below the breakaway speed of the tandem pump
(engine speed approx. 1000 rpm).

GR_FB3708012

Index

Explanation

Index

Explanation

1

Tandem pump (power-steering pump and active roll stabilization)

2

Connection for radial piston pump

3

Connection for vane-type pump

4

Drainage coil valve

5

2-pin plug-in connection

6

Supply to tandem pump

7

ECO valve (power-steering pump)

 

 


Structure and inner circuit

The drainage coil valve is connected by means of a 2-pin plug-in connection.

The drainage coil valve is a solenoid valve. The VDM control module supplies the drainage coil valve with current (approx. 0.85 Ampere).

GR_FB3708020

Index

Explanation

Index

Explanation

1

Drainage coil valve

 

 


Pin assignments

Pin

Explanation

12 V

Power supply drainage coil valve

Terminal 31E

Terminal 31, electronics earth for drainage coil valve


Characteristic curve and target values for tandem pump

During idling, the pump speed is approx. 750 rpm. At this idle speed, the tandem pump delivers a volumetric flow of approx. 5 l/min at approximately 3 bar. This ensures adequate system dynamics even at idle speed. At a pump speed of 1250 rpm, the maximum volumetric flow is limited to 9 l/min.

GR_FB3708021

Index

Explanation

Index

Explanation

1

Pump speed

2

Characteristic curve for tandem pump

3

Volumetric flow

 

 


Observe the following target values for the drainage coil valve:

Variable

Value

Voltage range

8 to 16 V

Response time at 20 °C and 13 V

≤ 40 ms

Current consumption at 25 °C and 13 V

approx. 1 A

Temperature range

-40 °C to 140 °C


Diagnosis instructions

Failure of the component

If the drainage coil valve fails, the following behaviour is to be expected:

No liability can be accepted for printing or other faults. Subject to changes of a technical nature