WDSBMW wiring diagrams
← Back

Pressure distributor for active seat, driver and/or passenger

Pressure distributor for active seat, driver and/or passenger

The pressure distributor distributes the air flow generated by the pneumatic pump to the 4 air cushions in the active seat. Two air cushions are arranged one above the other on the left-hand and right-hand seat cushions.
The pressure distributor automatically regulates the inflation and deflation of the air cushions.

Functional description

The pressure distributor in the active seat for the driver and/or passenger consists of the following components:

The pressure distributor in the active seat for the driver or passenger can be switched on as of terminal 15 On. The driver seat module (SMFA) and/or passenger seat module (SMBF) activates the pressure distributor in the active seat for the driver and/or passenger.

If the system is switched off via the active seat button, the 4 air cushions must be deflated.
Deflating: That means: If the pneumatic pump is switched off, the pressure distributor runs a complete work cycle.
After a timeout of more than 100 seconds, the power supply is interrupted automatically by the driver seat module (SMFA) and/or passenger seat module (SMBF).

If the system is not fully deflated after disconnecting the battery or resetting the seat module, activation takes place. The signal is sent by the micro-switch in the pressure distributor. If the pneumatic pump is switched off, the pressure distributor runs a complete work cycle.
After a timeout of more than 100 seconds, the power supply is interrupted automatically by the seat module.

GR_FB5208008

Index

Explanation

Index

Explanation

1

Pressure distributor for active seat, driver and/or passenger

2

Camshaft

3

Connections for the air ducts to the air cushions

4

Connection for supply with compressed air from the pneumatic pump

5

Signal disk

6

Transmission

7

Electric motor

8

Micro-switch

If the driving speed and lateral acceleration are above a defined value for approx. 0.25 seconds, the active seat function is disabled. The function indicator remains switched on. If the value is again undershot for approx. 3 seconds, the system resumes the function at the stopped position.

Structure and inner circuit

The pressure distributor in the active seat for the driver and/or passenger is connected to the driver seat module (SMFA) and/or passenger seat module (SMBF).

GR_FB5208009

Index

Explanation

Index

Explanation

1

Drive motor

2

Micro-switch


Pin assignments

Pin

Explanation

Terminal 31L

Terminal 31, load ground

U

Power supply via seat module

SIG

Signal line (signal from micro-switch)

1 pin not used.


Target values

Observe the following target values for the pressure distributor in the active seat, driver:

Variable

Value

Voltage range

9 to 16 V

Rated current

70 mA

Maximum current consumption (< 1 minute)

1 A

Temperature range

-40 to 85 °C


Diagnosis instructions

Failure of the component

If the pressure distributor for the active seat for the driver and/or passenger fails, the following behaviour is to be expected:

No liability can be accepted for printing or other faults. Subject to changes of a technical nature