Electric changeover valve for the exhaust flap

Electric changeover valve for the exhaust flap

The exhaust flap is integrated in the rear silencer.
The exhaust flap lowers the noise level at idle speed and in the engine speed range close to idle speed. This reduces the outlet noise to improve comfort for the customer. The reduction in outlet noise is approx. 8 dB.

Functional description

The engine management system activates the electric changeover valve. The partial vacuum applied opens the exhaust flap. Opening depends on the gear, engine speed as well as load. The partial vacuum applied opens the exhaust flap. On venting the diaphragm canister (vacuum system at static pressure), the exhaust flap is closed by a spring.

GR_FB1108046

Index

Explanation

Index

Explanation

1

Electric changeover valve for the exhaust flap

2

2-pin plug-in connection

3

vacuum line

4

Exhaust flap, cylinder bank 1

5

Exhaust flap, cylinder bank 2

 

 

 

Structure and inner circuit

A diaphragm canister is fixed onto the rear silencer exhaust pipes. The diaphragm canister is linked to the exhaust flap via an adjustment mechanism. From the electric changeover valve, the vacuum hose leads to the diaphragm canister.

GR_FB1108047

Index

Explanation

Index

Explanation

1

Electric changeover valve for the exhaust flap

 

 


Pin assignments

Pin

Explanation

Kl. 15N

Terminal 15, power supply

SIG

Activation of electric changeover valve


Activation and target values

The flap is closed without current when the engine is not running. While the vehicle is being driven, only the two states open or closed are present.
Activation of the exhaust flap depends on:

GR_FB1108057

Example:

Index

Explanation

Index

Explanation

1

Gear engaged

2

Exhaust flap closed

3

Exhaust flap opened

4

Reference point, engine speed


Observe the following target values for the electric changeover valve for the exhaust flap:

Variable

Value

Voltage range

9 to 16 Volts

Current consumption

1 A

Temperature range

-30 °C to 140 °C


Diagnosis instructions

Failure of the component

If the electric changeover valve for the exhaust flap fails, the following behaviour is to be expected:

General information

If a closed exhaust flap is defective, the exhaust system hisses at higher engine speeds. If a partially opened exhaust flap is defective, a humming noise is generated at idle speed.

No liability can be accepted for printing or other faults. Subject to changes of a technical nature