Which stepper motor is to be checked?
Which stepper motor is to be checked?
Please enter the ID code of the stepper motor to be checked
The order of the list of stepper motors describes the topological order of the stepper motors on the LIN bus. The stepper motors are switched in series on the LIN bus. The first listed stepper motor is the topological first stepper motor viewed from the control module for the climate control. If the LIN bus is interrupted at one position in the wiring harness, the location of the interruption can be detected by finding the topological first stepper motor that is no longer communicating with the control module. All of the topological the following stepper motors would also no longer communicate.
Climate control to the IHKA with FKA (4 zones)

ID code |
Explanation |
|---|---|
1 |
Footwell-flap motor, left |
2 |
Front left stratifying-flap motor |
3 |
Footwell flap motor, rear left |
4 |
Center left ventilation-flap motor |
5 |
Rear stratification flap motor, left |
6 |
Rear stratification flap motor, right |
7 |
Center right ventilation-flap motor |
8 |
Footwell-flap motor, right |
9 |
Footwell flap motor, rear right |
10 |
Defroster-flap motor |
11 |
Outside right ventilation-flap motor |
12 |
Front right stratifying-flap motor |
13 |
Outside left ventilation-flap motor |
14 |
Recirculated air flap motor |
15 |
Fresh air flap motor |
The order of the list of stepper motors describes the stepper motors switched in series on the LIN bus.
Detail view of the area of defrosting, side outlets, stratification

Air distribution flap |
Designation / Function |
|---|---|
30 |
Right stratification flap |
31 |
Left-hand stratification flap |
32 |
Outside left ventilation flap |
33 |
Left-hand defroster flap |
34 |
Right defroster flap |
35 |
Outside right ventilation flap |
36 |
Non-return flap |
ID code of the flap motor |
Designation of the flap motor |
|---|---|
2 |
Front left stratifying-flap motor |
8 |
Footwell-flap motor, right |
11 |
Outside right ventilation-flap motor |
12 |
Front right stratifying-flap motor |
Detail view of the ventilation and footwell areas

Air distribution flap |
Designation / Function |
|---|---|
36 |
Left-hand non-return flap |
37 |
Right non-return flap |
38 |
Right footwell flap |
39 |
Rear right footwell flap |
40 |
Left-hand ventilation flap |
41 |
Right ventilation flap |
ID code of the flap motor |
Designation of the flap motor |
|---|---|
4 |
Center left ventilation-flap motor |
7 |
Center right ventilation-flap motor |
8 |
Footwell-flap motor, right |
9 |
Footwell flap motor, rear right |
Detail view of the rear and footwell area

Air distribution flap |
Designation / Function |
|---|---|
42 |
Rear-right air conditioning flap |
43 |
Rear-left conditioning flap |
44 |
Rear right footwell flap |
45 |
Footwell flap, left |
46 |
Rear-left stratification flap |
47 |
Rear-right stratification flap |
ID code of the flap motor |
Designation of the flap motor |
|---|---|
1 |
Footwell-flap motor, left |
3 |
Footwell flap motor, rear left |
5 |
Rear stratification flap motor, left |
6 |
Rear stratification flap motor, right |