Exhaust-gas recirculation (EGR) DDE 4.0
Depending on the operating status, a certain quantity of exhaust gas is returned via the EGR valve into the exhaust tract in order to reduce pollutant emission.
Components
- EGR valve with vacuum unit
Installation position: at the intake port - Pressure converter for EGR valve
- Throttle valve with vacuum control module
Installation position: in the intake port - Pressure converter for throttle valve
Function of the EGR valve
The exhaust gas is fed through a bore hole in the cylinder head from the exhaust side to the intake side. The EGR valve connects this bore hole with the intake pipe.
The pressure converter connects the vacuum unit with the vacuum supply by means of hoses. Depending on the activation status and controlled by the DDE control module, it switches a variable vacuum to the vacuum unit. The pressure converter is activated by a square-wave signal with duty factors (= variable pulse width) between 5 and 95%.
Function of the throttle valve
The throttle valve serves to create increased vacuum in the intake pipe. The more tightly the throttle valve is closed, the more exhaust gas flows into the intake pipe.
Activation of the throttle valve - in the same way as activation of the EGR valve - is also by means of a pressure converter activated by the DDE control module.
Control
The quantity of recirculated exhaust gas influences the mass of the fresh air drawn in: The more exhaust gas is recirculated, the less fresh air is drawn in by the engine.
As a measurement of the recirculated exhaust gas volume, the fresh air mass taken in is used.
For the purpose of exhaust gas recirculation control, a nominal value of air mass is defined in a characteristic map for all operating conditions.
The pulse duty factors for the EGR valve and the throttle valve are calculated by the DDE control module from the deviation from the nominal and actual value of the air mass. The further the EGR valve is opened, the more tightly the throttle valve is closed.
If the control module detects a diskrepancy between the specified and actual intake air mass that is outside the permissible limits, a fault is stored.
Exhaust gas recirculation is deactivated
The following states lead to deactivation of the exhaust gas recirculation:
- Fault on the air-mass sensor
- Fault in control deviation EGR
- Fault in EGR controller
- Battery voltage < 8 V
- Injection rate > 34 mm3
- Engine start
- Engine speed < 650 rpm OR Engine speed > 5200 rpm
- Over-run mode AND engine speed > 2600 rpm
- Coolant temperature < 15°C OR Coolant temperature > 100°C
- Ambient pressure < 900 mbar
As reaction, the EGR valve is closed and the throttle valve opened.