Glow System DDE 4.0
The voltage for the preheater plugs is supplied via the preheater relay. The relay is switched by the DDE control module.
The heater plugs are designed as sheathed-element glow plugs.
Preheater time control
The preheating duration is dependent on the coolant temperature and battery voltage and is indicated by the preheater/DDE indicator.
Preheating
The preheating times can be seen from the following table:
|
Battery voltage |
||||
|---|---|---|---|---|---|
Coolant temperature |
10 |
11 |
13 |
14 |
15 |
-10 |
11 |
11 |
7 |
5 |
5 |
0 |
11 |
8 |
5 |
5 |
5 |
10 |
11 |
8 |
5 |
5 |
1 |
20 |
11 |
8 |
3 |
3 |
1 |
40 |
11 |
1 |
1 |
1 |
1 |
Troubleshooting
The DDE control module detects short circuit/interruption in the relay activation function.